7
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
MAINTENANCE
GENERAL CARE
1. When the jack is not in use, keep the ram fully lowered and the release
valve closed.
2. Keep the jack clean and occasionally apply lubricating oil to all pivot
points, front wheels & rear castors.
3. Periodically check the oil level as follows.
4. Check the pump piston and piston rod periodically for signs of corrosion.
Clean exposed areas with a clean oiled cloth.
5. In the event of damage or broken components, replacements are
available from CLARKE Parts & Service.
CHECKING/TOPPING UP THE OIL LEVEL
If the jack has been stored for long periods, check for oil leaks before use. If
necessary, check the oil level as follows:
1. Ensure the jack is fully lowered by turning the control valve fully anti-
clockwise.
2. Lift away the plastic tray and
remove the filler plug.
• The oil should be almost level
with the bottom of the oil filler
hole.
• Oil can be topped up using
CLARKE Hydraulic Oil (p/n
3050830 1 litre). Never use
brake fluid or instead of oil.
3. Purge any air from the system and replace the filler plug.
4. Dispose of old/spilled oil appropriately and wipe up any spillage.
ENVIRONMENTAL PROTECTION
One of the most damaging sources of environmental pollution is oil products.
Never throw away used hydraulic oil with domestic refuse or flush it down a
sink or drain. Collect any hydraulic oil in a leak proof container and take it to
your local waste disposal site.
If disposing of this product or any damaged components, do not dispose of
with general waste. This product contains valuable raw materials and should
be taken to your local civic amenity site for recycling of metal products.
Содержание 7623250