Clarke 7236042 Скачать руководство пользователя страница 5

5

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

ELECTRICAL CONNECTIONS

Before switching the product on, make sure that the voltage of your electricity supply is 
the same as that indicated on the rating plate. This product is designed to operate on 
230VAC 50Hz. Connecting it to any other power source may cause damage.

This product may be fitted with a non-rewireable plug. If it is necessary to change the 
fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or 
damaged, the plug must not be used until a suitable replacement is obtained.

If the plug has to be changed because it is not suitable for your socket, or due to 
damage, it should be cut off and a replacement fitted, following the wiring instructions 
shown below. The old plug must be disposed of safely, as insertion into a mains socket 
could cause an electrical hazard

.

If the colours of the wires in the power cable of this product do not correspond with the 
markings on the terminals of your plug, proceed as follows.

The wire which is coloured 

Blue

 must be connected to the terminal which is 

marked 

N

 or coloured 

Black

.

The wire which is coloured 

Brown

 must be connected to the terminal which 

is marked 

L

 or coloured 

Red

.

The wire which is coloured 

Yellow and Green

 must be connected to the 

terminal which is marked 

or  

or 

coloured 

Green.

.

We strongly recommend that this machine is connected to the mains supply 
via a Residual Current Device (RCD)

If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.

WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE 
MAINS SUPPLY.

WARNING! THE WIRES IN THE POWER CABLE OF THIS PRODUCT 
ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL   BROWN = LIVE  YELLOW AND GREEN = EARTH

Plug must be BS1363/A approved.

Always fit a 13 Amp fuse.

Ensure that the outer sheath of the cable is firmly held by the clamp

Neutral

(Blue)

Live

(Brown)

Earth

(Green and Yellow)

Содержание 7236042

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC04 17 SUBMERSIBLE PUMPS MODEL NO PSV3A PSV4A PSSV2A PVP11A PART NO 7236042 7236044 7236050 7236060...

Страница 2: ...d if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product ca...

Страница 3: ...cal wiring or equipment 4 Always store the pump out of reach of children and do not allow persons unfamiliar with these instructions to operate it 5 Never direct the discharge flow towards another per...

Страница 4: ...there is a person or animal still in the pool 11 Never install the pump on sand silt or mud which is likely to shift or collapse 12 Never modify this pump in any way Use it only for the purpose for w...

Страница 5: ...ard If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connecte...

Страница 6: ...unding water level changes As the water level rises the switch will float and start the pump As the water level falls so will the float switch until it stops the pump Float switches are factory set to...

Страница 7: ...E PUMP 1 ALWAYS raise and lower the pump using a rope attached to the lifting handle 2 Place the pump in a vertical position resting on a firm flat surface in the area that you want to drain If there...

Страница 8: ...re there is sufficient water for the float switch to rise and activate the pump 2 If required the range of operation of the float switch can be manually adjusted by positioning the float switch cable...

Страница 9: ...be cleaned out either by back flushing or by removing the base plate after undoing the retaining screws and cleaning out by hand 3 If the pump has been used for pumping swimming pool water or salty w...

Страница 10: ...d in the system 5 Inlet at base of pump is blocked Raise pump and clear openings 6 Vertical pumping distance too high Reduce height or change the pump discharge fitting 7 Impeller may be damaged Consu...

Страница 11: ...cut in 3 A foreign object has jammed the impeller Feature PSV3A PSV4A PSSV2A PVP11A Outlet Tread Dia 1 BSP 1 BSP 1 BSP 1 BSP Outlet Size 38mm 38mm 38mm 34mm Voltage 230 Vac 230 Vac 230 Vac 230 Vac Mo...

Страница 12: ...Cable Sheath 4 Top Housing 23 O Ring 5 Cable Entry Sheath 24 Adjusting Shim Washer 6 Cable Entry Gland 25 Impeller 7 Capacitor 8uF 26 Nut 8 Cable Gland 27 Main Pump Housing 9 Cable Holder 28 Steel Bal...

Страница 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM PSV3A PSV4A...

Страница 14: ...Body 31 Compression Ring 8 O ring 32 Bolt 9 Pump Rear Housing 33 Ground Bracket 10 Cable Entry Sheath 34 Locating Ring 11 Cable Sheath 35 Sealing Washer 12 Cable Gland 36 Base Cover Ring 13 Capacitor...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM PSSV2A...

Страница 16: ...29 Front Motor Cover 7 Main Pump Body 30 Mechanical Seal 8 O Ring 31 Adjusting Shim Washer 9 Pump Rear Housing 32 Shim Washer 10 Cable Entry Sheath 33 Impeller 11 Cable Gland 34 Nut 12 Capacitor 8uF 3...

Страница 17: ...17 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM PVP11A...

Страница 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PUMP PERFORMANCE GRAPHS...

Страница 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 20: ......

Отзывы: