background image

3

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

SPECIFICATION

PUMP PERFORMANCE CURVE

Maximum Delivery

100 L/min

Maximum Head

14 m

Maximum Suction Lift

7.5 m

On/Off Pressure

1.6/4.8 Bar

Ingress Protection Rating

IPx4

Supply

230V ~ 50Hz

Rated Power

1000 W

Outlet Thread Size

1” BSP

Weight

13.5 kg

Sound Power Level

73 dB LpA

Содержание 7230670

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1220 WATER PUMP MODEL NO CBM240E PART NO 7230670...

Страница 2: ...ture for a period of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or t...

Страница 3: ...ernational com SPECIFICATION PUMP PERFORMANCE CURVE Maximum Delivery 100 L min Maximum Head 14 m Maximum Suction Lift 7 5 m On Off Pressure 1 6 4 8 Bar Ingress Protection Rating IPx4 Supply 230V 50Hz...

Страница 4: ...is properly installed to prevent it from moving during operation and that the immediate area surrounding the pump is kept clear 6 ALWAYS maintain the pump with care and keep it clean for best safest...

Страница 5: ...er cable must agree with the markings on the plug Connect the BLUE wire to the terminal marked N Connect the BROWN wire to the terminal marked L Connect the YELLOW AND GREEN wire to the terminal marke...

Страница 6: ...ation around the motor Avoid situations where there is the risk of water coming into contact with the outside of the pump Neither the motor or the terminal box are designed to be waterproof These note...

Страница 7: ...dy from entering the pump This is particularly important in the case of multi stage pump such as the CBM240E A filter specifically designed for all pumps in the range is available from your CLARKE dea...

Страница 8: ...of the pump chamber and slowly fill the pump with water until all air is expelled NOTE If a filter is fitted to your pump it is recommended that you remove the brass plug on top of the unit and fill...

Страница 9: ...clear blockage Pump fails to prime Air leaks through suction hose joints damaged hose or damaged clamp Repair connections replace hose as necessary Blocked inlet hose Check pipeline for block age Chec...

Страница 10: ...flow of water by adjusting inlet outlet valves in system Resistance in inlet pipe caused by obstruction Check pipe and clean out as necessary Loose rotating component Return to your dealer for repair...

Страница 11: ...pump If you suspect the pump is blocked by silt leaf debris etc disconnect it from the power supply and back flush to clear any blockage using a garden hose You will need to disconnect the outlet hose...

Страница 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS CBM240E...

Страница 13: ...ring 35 O ring 8 End flange casting 36 Capacitor holder 9 O ring 37 Spring washer 10 O ring 38 Cable holder 11 Impeller 39 Earth screw 12 Pump body 40 Washer 13 Nut 41 Wave washer 14 Washer 42 Spring...

Страница 14: ...onal com or Service clarkeinternational com ACCESSORIES 1 BSP Hose adaptor 90o bend female Part No 7950190 1 BSP Plastic Foot Valve Filter FVF10 Part No 7950680 1 dia Reinforced Suction Delivery Hose...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: