SETTING UP THE PUMP

POSITIONING THE PUMP

1. Place the pump on a flat surface in the area that you want to drain.

• If there is sediment in the operating area, the pump should be placed 

vertically on house bricks, or similar.

• Ensure the pump is positioned with adequate space so that the 

movement of the float switch is not restricted - recommended minimum 
area of 50 x 50cm.

• ALWAYS raise and lower the pump using a rope attached to the lifting 

handle.

• Take all necessary precautions as described on page 3.

USING THE PUMP

1. Connect the mains plug to the mains supply.

• Always use a high sensitivity residual current device (RCD) which has a 

tripping current of less then 30mA.

2. Switch the mains power supply on.

• The pump will begin to drain water.

• As the water level falls, so will the float switch, until it stops the pump.

• You can adjust the position at which the float switch lead clips to the 

side of the pump. Adjusting the length of the float switch lead will 
change the depth of water at which the pump will turn on or off.

3. When pumping is finished, disconnect the pump from the mains power 

supply.

IMPORTANT: Do not allow the pump to run dry

WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE 
PUMP IF IT IS DAMAGED IN ANY WAY.

WARNING: THE WATER BEING PUMPED WILL BE POLLUTED IF THIS PUMP 
BECOMES DAMAGED AND LUBRICANT WITHIN THE PUMP ESCAPES.

Содержание 7230604

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC 1221 ISS4 1300W SUBMERSIBLE PUMP MODEL NO CSV4A PART NO 7230604...

Страница 2: ...iod of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with i...

Страница 3: ...r use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 DO NOT pump exp...

Страница 4: ...BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the term...

Страница 5: ...le hose not supplied to the pump outlet Suitable hoses are available from your local Clarke dealer FITTING THE HOSE ADAPTER 2 step adapter 2 hose 1 BSP 3 step adapter 1 hose 1 BSP 1 hose 1 Screw the 2...

Страница 6: ...ect the mains plug to the mains supply Always use a high sensitivity residual current device RCD which has a tripping current of less then 30mA 2 Switch the mains power supply on The pump will begin t...

Страница 7: ...guarantee Repairs must be carried out by your CLARKE dealer or contact the CLARKE Service Department on 020 8988 7400 STORAGE When the pump is not being used for extended periods clean and dry it thor...

Страница 8: ...moving 7 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the outlet is not clogged or obstructed...

Страница 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS LIST DIAGRAM...