PUMP POSITIONING AND HOSE CONNECTION

Remove all packaging and make sure that the unit contains no visible 
damage. Dispose of all packaging appropriately.

CONNECTING THE PUMP

1. Connect the hose to the outlet adaptor.

2. Always use the largest diameter hose possible as any restriction will reduce 

capacity and put unnecessary strain on the motor especially if a long run 
of discharge hose is being used.

•  The outlet adaptor fitting allows for connection of 25 mm (1”) hose 

which should be secured with a hose clamp.

• Suitable hoses are available from your local CLARKE dealer.

POSITIONING THE PUMP

1. It may be safer to raise and lower the pump into deep water using a rope 

attached to the lifting handle.

2. Place the pump in a vertical position resting on a firm, flat surface in the 

area that you want to drain. If there is sediment in the operating area, the 
pump should be placed vertically on house bricks or similar but ensure they 
are not likely to collapse. Never

 

position the pump on sand, silt, mud or 

ground which is likely to collapse.

3. Keep the pump clear of sediment by standing it on a platform or brick or 

suspending from a rope attached to the handle if the pump is to be used 
where there may be silt or mud etc (e.g. garden ponds).

4. Route the hose as straight as possible. Excessive bending of the hose could 

obstruct the flow of water, reduce the pumping volume or clog the pump 
with mud, thus disabling the pumps function. If the hose is kinked at its base 
it will create air pockets in the pump, causing it to operate in a partially dry 
state. Take care to straighten any kinks or bends in the hose.

5. DO NOT operate the pump if the water is too shallow. This will be below the 

level of the outlet elbow with the impeller fully immersed. The pump inlet 
must be fully submerged before being switched on.

6. Allowance must also be made for the overall width of the pump including 

the outlet elbow on one side.

• When the pump is being used in a permanent or semi-permanent 

installation, a non-return valve should be fitted in the delivery hose. 
Suitable hoses and valves are available from your CLARKE dealer.

• Take all necessary precautions as described on pages 4-5.

Содержание 7230296

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC08 22 ORIGINAL INSTRUCTIONS 560W PUDDLE RESIDUE PUMP MODEL NO CPRP560 PART NO 7230296...

Страница 2: ...mp The pump is provided with a thermal overload cut out so that in the event that the pump becomes overheated due to becoming blocked etc it will shut off automatically When the blockage has been clea...

Страница 3: ...ce 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com OVERVIEW FEATURES 1 Water inlet screen 2 Power cable with plug 3 Outlet hose adaptor 4 Lifting handle Pump Perf...

Страница 4: ...the pump 3 NEVER direct the water discharge towards electrical wiring or equipment 4 ALWAYS store the pump out of reach of children and do not allow persons unfamiliar with these instructions to opera...

Страница 5: ...lapse 11 NEVER modify this pump in any way Use it only for the purpose for which it is designed 12 NEVER allow the pump to run dry or operate out of the water 13 Submersible pumps should always be sub...

Страница 6: ...in accordance with the WEEE regulations in relation to the treatment recycling recovery and environmentally sound disposal of the WEEE In effect this means that this product must not be disposed of w...

Страница 7: ...in the power cable do not agree with the markings on the plug proceed as follows The BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the ter...

Страница 8: ...re not likely to collapse Never position the pump on sand silt mud or ground which is likely to collapse 3 Keep the pump clear of sediment by standing it on a platform or brick or suspending from a ro...

Страница 9: ...r may be seen escaping from the discharge hose 4 Disconnect from the power supply when the water has been pumped out Avoid running the pump continuously if the discharge hose has become obstructed and...

Страница 10: ...it should be flushed through with clean water before storage 5 When the pump is not being used for extended periods clean and dry it thoroughly and store in indoors if the pump is left in water it sho...

Страница 11: ...onnect from the mains supply and remove any objects that may be obstructing the impeller 6 If the pump still fails to start consult your CLARKE dealer PUMP WILL START BUT NOT PUMP 1 Check that the inl...

Страница 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS...

Страница 13: ...he purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY UK...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY EU...

Страница 16: ......

Отзывы: