Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

ELECTRICAL CONNECTIONS

This product can be connected to one of the following power supplies:

Connecting it to any other power source may cause damage.

This product requires a fitted industrial plug to BS-EN 
60309 (not supplied), for use with a 110 volt supply. On 
no account must a 230V, 13 amp (BS1363) plug be 
used.

If using a portable 110V transformer make sure it has a 
rated capacity sufficient to take the load of the 
pump.

To fit the plug, proceed as follows:

1. Undo the socket screws & remove the rear section.

2. Rotate the cable clamp clear of the terminals.

3. Feed the cable through the rear gland in the plug.

4. Remove the cable sheath to the required lengths 

as shown in the diagram.

5. Terminate the correct wires in the 

correct terminal blocks.

6. Remove the cable clamp screws. Clip 

the cable clamp back into position and 
place the clamp around the outer 
sheath of the cable. Replace the screws 
and tighten until the cable is securely 
held.

7. Replace the rear cover and tighten the cover screws.

If in any doubt, consult a qualified electrician. DO NOT attempt any repairs 
yourself.

WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO A 
POWER SUPPLY.

• 110V Generator

• 110V Isolating Transformer

• 110V Site supply

• 230V Generator via a 110V transformer.

Содержание 7230102

Страница 1: ...FOR USE WITH A 110V SUPPLY ONLY OPERATION MAINTENANCE INSTRUCTIONS LS0620 ISS 5 ORIGINAL INSTRUCTIONS SUBMERSIBLE DIRTY WATER PUMP MODEL NO DWP210A PART NO 7230102...

Страница 2: ...proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be return...

Страница 3: ...r use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump exp...

Страница 4: ...international com or Service clarkeinternational com PART IDENTIFICATION Remove all packaging and make sure that the unit displays no visible damage Dispose of all packaging appropriately 1 WATER INLE...

Страница 5: ...the rear section 2 Rotate the cable clamp clear of the terminals 3 Feed the cable through the rear gland in the plug 4 Remove the cable sheath to the required lengths as shown in the diagram 5 Termina...

Страница 6: ...d to the lifting handle Take all necessary precautions as described on page 3 The pump inlet must be fully submerged before the pump is switched on 3 Connect the plug to the power supply 4 Switch the...

Страница 7: ...r for advice CLEANING 1 Check the pump installation regularly to ensure the water inlet is clear of leaves or other debris 2 Take extra care to remove any debris from around the impeller NOTE Do not a...

Страница 8: ...ECIFICATIONS DWP210A Voltage 110V 50Hz Outlet Diameter 2 BSP inc 2 Adaptor Rated input Power 940W Power at Maximum Flow 1140 W Maximum Head Height 10 m Maximum Output 567 l min Maximum Depth 2 m Max W...

Страница 9: ...switch in OFF position lift float to check switch 8 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check t...