MAINTENANCE

This pump should require no maintenance other than regular cleaning.

If the pump starts to show signs of wear or damage, contact your CLARKE 
dealer for advice.

CLEANING

1. Check the pump installation regularly to ensure the base inlet is clear of 

leaves or other debris.

2. Take extra care to remove any debris from around the impeller.

NOTE:

Do not attempt to repair the pump yourself, as you may damage the 
waterproof seal and invalidate your guarantee. Repairs must be 
carried out by your CLARKE dealer, or contact the CLARKE Service 
Department, on 020 8988 7400.

STORAGE

When the pump is not being used for extended periods, clean and dry it 
thoroughly and store in indoors. if the pump is left in water, it must be run at 
least once a week to prevent it from seizing up.

WARNING: BEFORE CHECKING THE CONDITION OF THE PUMP, ENSURE IT 
IS UNPLUGGED FROM THE MAINS SUPPLY. IF THE UNIT IS HARD WIRED, 
ENSURE THE CIRCUIT BREAKER IS OPEN.

Содержание 7230096

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC1221 ISS 5 ORIGINAL INSTRUCTIONS SUBMERSIBLE SEWAGE PUMP MODEL NO SWP900A PART NO 7230096...

Страница 2: ...red with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guar...

Страница 3: ...and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 DO NOT pump explosive...

Страница 4: ...national com or Service clarkeinternational com OVERVIEW Remove all packaging and make sure that the unit contains no visible damage Dispose of all packaging appropriatly 1 FLOAT SWITCH 4 HANDLE 2 WAT...

Страница 5: ...BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the ter...

Страница 6: ...ins plug to a high sensitivity residual current device RCD which has a tripping current of less then 30mA 4 Switch the mains power supply on The pump will begin to drain water As the water level falls...

Страница 7: ...bris from around the impeller NOTE Do not attempt to repair the pump yourself as you may damage the waterproof seal and invalidate your guarantee Repairs must be carried out by your CLARKE dealer or c...

Страница 8: ...ur CLARKE dealer PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the discharge tube is not clogged or obstructed 3 The head may be too great i e you are trying to lift...

Страница 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 10: ...over 3 Footing 15 Screw 27 O Ring 4 Casing Cover 16 Mechanical Seal 28 Upper Motor Cover 5 O Ring 17 O Ring 29 Gland Cover 6 Screw 18 Rotor 30 O Ring 7 O Ring 19 Motor Frame 31 Screw 8 Casing 20 Beari...

Страница 11: ...in 1 3 Diameter 26 piece assorted hose clip set in various sizes Including 8 x16mm 6 x 22mm 4 x 25mm 2 x 28mm 2 x 35mm 4 x 40mm clips Zinc plated for corrosion resistance Voltage 230V 50Hz Outlet Thre...

Страница 12: ......

Отзывы: