Clarke 7120405 Скачать руководство пользователя страница 2

2

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

INTRODUCTION

Thank you for purchasing this Clarke Water Pump.

This non-submersible centrifugal pump is ideal for a range of domestic and 
light agricultural purposes.

It is designed to pump clean water in gardens for spraying and irrigation and 
for pumping water to greenhouses. It can also be used for boosting running 
water feed pressure (not drinking water) and for pumping out wells and 
ponds. It is not designed for use with contaminated or salt water. If used for 
pumping water from a pond, extra filtering measures should be taken to 
isolate any larger particles.

Before attempting to use this product, please read this manual thoroughly and 
follow the instructions carefully. In doing so you will ensure the safety of yourself 
and that of others around you, and you can look forward to your purchase 
giving you long and satisfactory service.

Your CLARKE water pump has been designed to give long and trouble free 
service. If, however, having followed the instructions in this booklet carefully, 
you encounter problems, take the unit to your local Clarke dealer.

Please keep these instructions in a safe place for future reference.

GUARANTEE

This product is guaranteed against faulty manufacture for a period of 12 
months from the date of purchase. Please keep your receipt which will be 
required as proof of purchase.

This guarantee is invalid if the product is found to have been abused or 
tampered with in any way, or not used for the purpose for which it was 
intended.

Faulty goods should be returned to their place of purchase, no product can 
be returned to us without prior permission.

This guarantee does not effect your statutory rights.

WARNING: THIS SYMBOL IS USED THROUGHOUT THE USER GUIDE 
WHENEVER THERE IS A RISK OF PERSONAL INJURY. ENSURE THAT 
THESE WARNINGS ARE READ AND UNDERSTOOD AT ALL TIMES.

Содержание 7120405

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1020 rev 3 2 ELECTRIC WATER PUMP MODEL NO ECP20A1 PART NO 7120405...

Страница 2: ...around you and you can look forward to your purchase giving you long and satisfactory service Your CLARKE water pump has been designed to give long and trouble free service If however having followed...

Страница 3: ...allow persons unfamiliar with these instructions to instal or operate the pump 6 ALWAYS ensure that the pump is properly installed to prevent it from moving during operation and that the immediate ar...

Страница 4: ...erating position Mount the pump on raised blocks or a purpose built platform to protect it from flooding Some kind of anti vibration mounting is also desirable Always ensure there is adequate air circ...

Страница 5: ...rical hazard To ensure that the colours of the wires in the power cable correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connected...

Страница 6: ...hose between any rigid pipework and the pump We recommend that you always use pipes hoses with a minimum diameter of 2 51 mm Any restriction in the pipeline will greatly reduce the flow Ensure that th...

Страница 7: ...r well providing the vertical distance between the foot valve and the pump does not exceed the 8 metres specified for this pump It is essential that all connections and hoses are airtight or the syste...

Страница 8: ...tlet as shown NOTE As the priming hole is quite small it is necessary to fill the inlet suction pipe with water before connecting to the pump and top up through the priming port once the pipe is conne...

Страница 9: ...riming process and it is important that a non return valve be fitted to the end of the suction pipe 4 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry...

Страница 10: ...om the weather If the pump is seized following a period of inactivity it may be possible to free it off Ensure the pump power supply is turned off before by inserting a screwdriver into either the inf...

Страница 11: ...ear blockage Pump fails to prime Air leaks through suction hose joints damaged hose broken clamp damaged Repair connections replace hose as necessary Blocked inlet hose Check pipeline for block age Ch...

Страница 12: ...n loss of flow Blockage of inlet pipe Check pipeline for blockage Undue vibration or noise Excessive flow of water Decrease flow of water by adjusting inlet outlet valves in system Resistance in inlet...

Страница 13: ...x4 splashing water Duty Cycle S1 Continuous Supply 230V 50Hz 1ph Rated Input Power 1700 W Outlet Thread Size 2 BSP Weight 28 2 kg Length x Width x Height 450 x 242 x 325 mm Sound Pressure Level 63 0...

Страница 14: ...15 Pump Support 28 Fairlead 3 O Ring 16 Drops Guard 29 Stand 4 Nut 17 Spring Washer 30 Stator Winding 5 Snap Ring 18 Bolt 31 Bearing 6 Washer 19 Motor Housing 32 Rotor 7 Key 20 Terminal Board 33 Beari...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: