Clarke 6939000 Скачать руководство пользователя страница 5

5

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

ELECTRICAL CONNECTIONS

Before switching the product on, make sure that the voltage of your electricity supply is 
the same as that indicated on the rating plate. This product is designed to operate on 
230VAC 50Hz. Connecting it to any other power source may cause damage.

This product may be fitted with a non-rewireable plug. If it is necessary to change the 
fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or 
damaged, the plug must not be used until a suitable replacement is obtained.

If the plug has to be changed because it is not suitable for your socket, or due to 
damage, it should be cut off and a replacement fitted, following the wiring instructions 
shown below. The old plug must be disposed of safely, as insertion into a mains socket 
could cause an electrical hazard

.

If the colours of the wires in the power cable of this product do not correspond with the 
markings on the terminals of your plug, proceed as follows.

The wire which is coloured 

Blue

 must be connected to the terminal which is 

marked 

N

 or coloured 

Black

.

The wire which is coloured 

Brown

 must be connected to the terminal which 

is marked 

L

 or coloured 

Red

.

The wire which is coloured 

Yellow and Green

 must be connected to the 

terminal which is marked 

or  

or 

coloured 

Green.

.

We strongly recommend that this machine is connected to the mains supply 
via a Residual Current Device (RCD)

If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.

WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE 
MAINS SUPPLY.

WARNING! THE WIRES IN THE POWER CABLE OF THIS PRODUCT 
ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL   BROWN = LIVE  YELLOW AND GREEN = EARTH

Plug must be BS1363/A approved.

Always fit a 13 Amp fuse.

Ensure that the outer sheath of the cable is firmly held by the clamp

Neutral

(Blue)

Live

(Brown)

Earth

(Green and Yellow)

Содержание 6939000

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC0715 INFRARED WALL HEATERS MODEL NO CFI 1800 1800L PART NO 6939000 6939002 ...

Страница 2: ... it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL RECYCLING POLICY Through purchase of this product the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment recycling recover...

Страница 3: ... facing combustible materials such as screens workshop furniture etc 3 Disconnect the heater from the power supply when not in use 4 Never place anything on top of the heater so as to impede free air flow 5 The heater is resistant to splashing but should be sheltered from direct rainfall as should the power cable plug and supply outlet socket An overhanging roof or other shelter should be used to ...

Страница 4: ...e this heater in small rooms when occupied by persons unable to leave the room on their own unless constant supervision is provided ELECTRICAL SAFETY 1 Make sure that the voltage on the rating label is the same voltage as the power supply If in doubt consult a qualified electrician 2 Never modify the plug in any way Do not use adaptor plugs with earthed appliances Correct plugs and outlets will re...

Страница 5: ...zard If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connected to the terminal which is marked N or coloured Black The wire which is coloured Brown must be connected to the terminal which is marked L or coloured Red The wire which is coloured Yellow and Green ...

Страница 6: ... between the heater and any obstruction including walls or other combustible surfaces Always position the heater facing the centre of the space to be heated not pointing directly at any nearby surfaces Never place any objects on or against the heater Any equipment or furniture should be a safe distance away as they could be adversely affected by heat Take care that the heat is not directed at curt...

Страница 7: ...there is any serious build up of dirt wipe thoroughly with a damp cloth Take care that no moisture enters the heater 2 Inspect the power cable for damage Undue heat will cause the cable to stiffen and crack in which case it should be replaced 3 Ensure heating elements are free of dust use compressed air to clean if possible Always wear a dust mask if performing this operation 4 Refer to your Clark...

Страница 8: ... blow repeatedly consult your Clarke dealer No power at socket outlet Insert plug into a suitable socket Input voltage incorrect Ensure power supply matches the rating on the label Lights not working Defective LED array Consult your Clarke dealer for replacement Defective switch Consult your Clarke dealer for replacement Model CFI1800 CFI1800L Dimensions L x W x H 220 x 652 x 228 mm 220 x 890 x 22...

Страница 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM ...

Страница 10: ... LED Bulb Assembly 36 Nut 9 LED Holding Bracket 37 Self tapping Screw 10 LED Housing 38 Cable Clip 11 Self tapping Screw 39 Seal 12 Connecting Disc 40 Switch Bracket 13 Stainless Steel Ball 41 Switch 14 Spring 42 Control Box 15 LED Module Side Panel 43 Cable Bush 16 Heater Side Panel 44 Internal Wiring Loom 17 Heater Panel 45 Power Cable Plug 18 Reflector Bracket 46 Plastic Plug 19 Heating Tube El...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 12: ......

Отзывы: