7
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
ELECTRICAL CONNECTIONS
This heater MUST be connected to a 400 Volt, 3 phase 50Hz supply through a
suitably rated isolator switch. It cannot be operated from a single phase
supply.
In addition to the cable fitted to the
heater, a DCL16B extension lead can
be used. This is fitted with a red 5 pin
16 amp industrial plug to EN 60309
with 16A socket. (CLARKE part No
6925233).
If in any doubt, consult a qualified electrician. DO NOT attempt any electrical
repairs yourself.
OPERATION
1. Put the heater in a level position
on a flat surface and at a safe
distance from flammable
materials. Keep a minimum of 2m
clearance all round.
2. Connect the heater to a suitable
power supply.
3. Set the thermostat control to the
maximum setting (fully clockwise).
WARNING: THE INSTALLATION OF THIS APPLIANCE SHOULD BE CARRIED
OUT BY A COMPETENT ELECTRICIAN AND BE IN ACCORDANCE WITH THE
CURRENT IEE WIRING REGULATIONS (BS7671-2:2008).
WARNING: DO NOT USE THIS HEATER IN SMALL ROOMS WHEN THEY ARE
OCCUPIED BY PERSONS NOT CAPABLE OF LEAVING THE ROOM ON THEIR
OWN, UNLESS CONSTANT SUPERVISION IS PROVIDED.
CAUTION: SOME PARTS OF THIS PRODUCT CAN BECOME VERY HOT AND
CAN CAUSE BURNS. PARTICULAR ATTENTION HAS TO BE GIVEN WHERE
CHILDREN AND VULNERABLE PEOPLE ARE PRESENT.
Содержание 6925238