ELECTRICAL CONNECTIONS
DEVIL 371SPD (110V) UNIT
This 110V heater is fitted with a 32 amp, three pin industrial plug to EN 60309
and MUST be connected to a 110 volt, 1 phase 50 Hz supply through a suitably
fused isolator switch. On no account must a 230V, 13 amp (BS1363) plug be
used.
NOTE:
If a portable 110V transformer is used, make sure it has a rated
capacity sufficient to take the load of the heater.
If the heater is hard wired into the electrical system all work must be carried
out in accordance with IEE regulations.
If the plug has to be changed due to damage, a replacement should be
fitted, following the wiring instructions shown below. The old plug must be
disposed of as insertion into a 110v socket could cause an electrical hazard.
If the colours of the wires in the power cable of this product do not correspond
with the markings on the terminals of your plug, proceed as follows.
• The
Blue
wire must be
connected to the terminal
which is marked
N
or
Neutral
.
• The
Brown
wire must be
connected to the terminal
which is marked
L
or
Live
.
• The
Yellow
wire must be
connected to the terminal
which is marked
E
or
Earth
.
If in any doubt, consult a
qualified electrician. DO NOT
attempt any repairs yourself.
WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL BROWN = LIVE YELLOW = EARTH
Plug must be BS60309 approved.
Neutral
Live
Earth