10
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
NOTE:
In case of emergency, close the switch
cover quickly, cover will latch down
and motor will be switched OFF. To
switch OFF normally, press OFF button,
(red button ‘O’), always close cover to
prevent accidental starting.
MAINTENANCE
Always inspect the machine before use and ensure it is in top condition.
Regularly inspect the filter for damage before use and replace if necessary.
Regularly check the tightness of the filter, filter bag and locking ring.
Excessive dust in the motor can cause overheating. Ensure all air vents are
clear. To avoid eye injury or adverse reaction to dust, clean the machine by
cleaning out the air vents using a vacuum cleaner.
Check the power cable to ensure it is sound and free from cracks, bare wires
etc. avoid using solvents when cleaning plastic parts. Most plastics are
susceptible to damage from various types of commercial solvents.
All bearings etc, in this machine are lubricated with a sufficient amount of high
grade lubricant for the machine’s lifetime under normal operating conditions,
therefore no further lubrication is required.
Occasionally it may be necessary to manually clean the impeller, to do this
proceed as follows.
1. Switch OFF and unplug the machine from the electrical supply.
2. Remove 12 screws securing the inlet cover, (6), and remove cover to
expose the impeller.
3. Clean impeller using a brush, cleaning cloth and vacuum cleaner
CAUTION: Beware of sharp edges.
If any repairs (other than the above cleaning) become necessary, it should be
carried out by an authorised service centre.