JUMP STARTING

NOTE: 

This device will not jumpstart a vehicle if the battery is very low or 

completely flat.

CONNECTING THE SMART CABLE TO THE POWER PACK

1. When jumpstarting, a minimum of 

3 of the power indicator lights 
located on top of the device must 
be lit. Recharge the device if 
required.

2. Lift the rubber plug and insert the 

EC5 connector of the smart lead 
into the power pack. 

• The red & green LEDs on the 

smart lead flash alternately.

CONNECT THE JUMP START LEADS TO THE BATTERY

1. Connect the red clamp to the unearthed battery terminal first, (this is 

usually the positive (+ve) terminal and coloured RED).

2. Connect the black clamp to the earthed battery terminal, (this is usually 

the negative (-ve) terminal and coloured BLACK)

3. Once you have connected the leads you have 30 seconds to try and start 

the vehicle, otherwise you will need to remove the leads and reattach 
them.

WARNING: SOME VEHICLE ELECTRONIC EQUIPMENT MAY BE DAMAGED 
BY JUMP STARTING. ALWAYS CHECK WITH THE VEHICLE HANDBOOK.

Содержание 6239005

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0620 ISS 2 ORIGINAL INSTRUCTIONS JUMP STARTER MODEL NO JSM300 PART NO 6239005...

Страница 2: ...f the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can b...

Страница 3: ...t the engine whilst the unit is being charged 9 NEVER attempt any repairs yourself If you have a problem with the unit contact your local CLARKE dealer 10 Always keep your body and clothing dry Never...

Страница 4: ...king with lead acid batteries 21 NEVER allow the cables to become wrapped around the operator or any other person 22 Wipe the body of the unit clean using a soft damp cloth do not use abrasives to cle...

Страница 5: ...or Service clarkeinternational com OVERVIEW NO DESCRIPTION NO DESCRIPTION 1 Worklight 6 Jumpstart Lead Socket 2 Charger Input Socket 7 Power Indicator Lights 3 12V DC Output Socket 8 On Off Button 4 U...

Страница 6: ...s charger or cigar lighter adapter into the charger input socket 3 If you are using the cigar lighter adapter start the engine 4 Connect the other end to either the mains supply or cigar lighter socke...

Страница 7: ...e ON OFF button again The work light flashes with the morse code SOS pattern 4 Push the ON OFF button again to turn the work light off USB POWER SUPPLY This will supply a maximum of 2 1A at 5V 1 Put t...

Страница 8: ...Service clarkeinternational com DC POWER SUPPLY 1 Insert the small fly lead into the power pack 2 Install the connector you need onto the other end of the fly lead 3 Insert the connector into the devi...

Страница 9: ...or of the smart lead into the power pack The red green LEDs on the smart lead flash alternately CONNECT THE JUMP START LEADS TO THE BATTERY 1 Connect the red clamp to the unearthed battery terminal fi...

Страница 10: ...OR A MAXIMUM OF 6 SECONDS If the engine does not start within this time SWITCH OFF the ignition and WAIT FOR AT LEAST 3 MINUTES BEFORE TRYING AGAIN 2 Once the engine is running disconnect the clamps w...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 12: ......

Отзывы: