![Clarke 6012100 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/clarke/6012100/6012100_operation-and-maintenance-instructions-manual_2616199015.webp)
15
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
2. Switch ON using the switch
located on the rear panel.
•
The digital display on the front
panel will come on and show the
current setting in amps.
•
If the machine stops at any time,
the thermal overload device may
have intervened. Wait until the
welder has cooled sufficiently
before restarting work.
3. Select the appropriate welding
rod and fit it into the welding rod
holder.
•
When the machine is on, the
menu will display the size of the
electrode fitting to the holder.
The following sizes can be used and are available from your CLARKE dealer.
See also page 28.
4. Attach the work clamp to the workpiece as close as possible to the area
being welded. Clean with a wire brush where necessary to ensure the
connection is as clean as possible.
MACHINE
ROD DIAMETER
WORKPIECE THICKNESS
MMA/TIG120,160,200
1.6 mm
1.5 - 2.0 mm
MMA/TIG120,160,200
2.5 mm
2.5 - 3.0 mm
MMA/TIG120,160,200
3.2 mm
3.5 - 4.5 mm
MMA/TIG160 & 200
4.0 mm
5.0 - 8.0 mm