CONNECTING THE POWER CABLE
This security light is not supplied with an electric cable. It must be connected
to a 220V - 240 VAC, 50 Hz power supply in accordance with the IEE Wiring
Regulations BS7671.
In case of doubt during the installation, contact a qualified electrician.
The power cable should exit the
building or other supporting structure
in such a way as to line up with the
security light and be able to pass
through the central hole in the
bracket as shown.
A drip loop should be left in the cable
to prevent rainwater running into the
lamp electrical compartment.
NOTE:
Mounting holes are 70mm
apart.
Wiring up this light should be carried out as follows:
1. Remove the cable gland and
rubber washer from the cable inlet
and retain.
• The illustration shows the gland
and washer removed.
2. Remove the terminal box cover by
unscrewing the four securing
screws.
3. Remove the screws securing the
cable clamp.
4. Thread the cable gland, followed by the rubber washer over the cable,
then thread the cable through the cable inlet in the junction box.
5. Carefully strip the outer insulation from the conductors for a distance of
approx. 30mm taking care not to damage the conductor insulation.
6. Strip the conductor insulation, for a distance of approx. 8mm and twist the
strands together, on each conductor.
7. Identify the terminals and connect the conductors accordingly as
indicated on page 7. A = Blue (neutral), B = Brown (Live).