5
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
GAS CONSUMPTION
Below is the gas requirement chart from a typical gas supplier for their range
including the bottle requirements. Should a smaller than recommended bottle
be used, then the gas exchange from a liquid to a gas will be rapid and cause
the bottle valve to freeze.
.
MAINTENANCE
The torches are maintenance free, but the user should make visual checks
before use to ensure all connections are secure and the gas hose is in perfect
condition.
If the nozzle becomes sooted, dismantle the burner and remove the injector
nozzle to clean with petrol and a brush. DO NOT poke sharp wire etc, through
the holes in the nozzle.
To remove the filter from the nozzle for cleaning, grasp the nozzle with a pair of
mole grips or very carefully secure in a vice, then unscrew the filter.
The parts on the following pages are all available from your CLARKE dealer.
BURNER DIAMETER
(MM)
POWER (kW)
CONSUMPTION
gr/h
GAS BOTTLE SIZE &
QTY
10
1.4
100
4 Kg X 1
14
1.7
120
4 Kg X 1
17
2
140
4 Kg X 1
20
2.1
150
4 Kg X 1
25
3.7
265
4 Kg X 1
35
6.3
450
4 Kg X 1
45
19.5
1400
47 Kg x 1
50
28
2000
47 Kg x 1
60
35
2500
47 Kg x 2
76
54
3850
47 Kg x 2
45 TURBO
29.5
2100
47 Kg x 1
50 TURBO
33
2350
47 Kg x 2
60 TURBO
54
3850
47 Kg x 2