background image

7

ELECTRICAL CONNECTIONS

Before switching the product on, make sure that the voltage of your electricity supply is 
the same as that indicated on the rating plate. This product is designed to operate on 
230VAC 50Hz. Connecting it to any other power source may cause damage.

This product may be fitted with a non-rewireable plug. If it is necessary to change the 
fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or 
damaged, the plug must not be used until a suitable replacement is obtained.

If the plug has to be changed because it is not suitable for your socket, or due to 
damage, it should be cut off and a replacement fitted, following the wiring instructions 
shown below. The old plug must be disposed of safely, as insertion into a mains socket 
could cause an electrical hazard.

If the colours of the wires in the power cable of this product do not correspond with the 
markings on the terminals of your plug, proceed as follows.

• The 

Blue

 wire must be connected to the terminal marked 

N

 or coloured 

Black.

• The 

Brown

 wire must be connected to the terminal marked 

L

 or coloured 

Red.

• The 

Yellow and Green

 wire must be connected to the terminal marked 

or 

 or coloured 

Green

.

We strongly recommend that this machine is connected to the mains supply 
via a Residual Current Device (RCD). If in any doubt, consult a qualified 
electrician. DO NOT attempt any repairs yourself.

WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE 
MAINS SUPPLY.

WARNING! THE WIRES IN THE POWER CABLE OF THIS PRODUCT 
ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL      BROWN = LIVE     YELLOW AND GREEN = 
EARTH

Plug must be BS1363/A approved.

Always fit a 13 Amp fuse.

Ensure that the outer sheath of the cable is firmly held by the clamp

Neutral

(Blue)

Live

(Brown)

Earth

(Green and Yellow)

Содержание 2241000

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1120 ISS 3 AIR COMPRESSOR MODEL NO BANDIT IV PART NO 2241000...

Страница 2: ...This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is fou...

Страница 3: ...elf against electric shock Never operate the compressor in wet or damp locations 4 NEVER over reach Keep your proper footing and balance at all times to enable better control of the compressor in unex...

Страница 4: ...ressure of 10 bar or more should be used Never attempt to repair damaged hoses 8 NEVER abuse the compressor by standing on it AIRLINE HOSES 1 ALWAYS ensure that equipment or power tools used in conjun...

Страница 5: ...he compressor repaired by a qualified service engineer Do not use the compressor if the On Off switch does not operate correctly 7 KEEP THE MOTOR AIR VENTS CLEAR Keep the motor vents clear and free fr...

Страница 6: ...be worn This compressor contains surfaces which may get hot during operation Never operate with the motor housing removed Risk of accidental start up The compressor could start automatically in the ev...

Страница 7: ...e colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The Blue wire must be connected to the terminal marked N...

Страница 8: ...SSEMBLY FIT THE AIR FILTER 1 Remove the travel plug 2 Screw the air filter into position The air filter must be hand tight only FIT THE OIL FILLER CAP 1 Remove the travel plug 2 Insert the oil filler...

Страница 9: ...ng Set the ON OFF switch to the OFF position pushed down Make sure that the compressor is on level ground Make sure that the supply voltage matches the voltage shown on the data label CHECK THE OIL LE...

Страница 10: ...ap back into position OPERATION If the compressor has not been used for more then 24 hours open the drain valve on the bottom of the reservoir and drain any condensate which has collected See page 13...

Страница 11: ...fully pressurised It will then shut down The compressor will start up again when the pressure in the reservoir decreases SET THE OUTPUT PRESSURE 1 Use the pressure regulator to set the output pressur...

Страница 12: ...ose TURNING THE COMPRESSOR OFF 1 Follow steps 1 3 in Removing Tools From The Air Hose above 2 Disconnect the compressor from the power supply 3 Slowly open the outlet valve to depressurise the reservo...

Страница 13: ...thermal overload device If the motor gets too hot the thermal overload device cuts the power which prevents damage to the motor If the thermal overload device operates let the motor cool down for 5 mi...

Страница 14: ...1 Remove the filter from the compressor 2 Remove the filter cover from the filter 3 Remove the filter from the filter cover 4 Clean the sponge and the filter cover using a soft brush If necessary the...

Страница 15: ...hese may be aggressive to the plastic parts Always disconnect the hose and any air tools from the compressor before cleaning STORAGE Disconnect the mains plug and ventilate the compressor and any conn...

Страница 16: ...t pressure and overheats easily Compressor head gasket blown or valve broken 1 Return the machine to your nearest service agent Compressor does not start The reservoir has already fully pressurised 1...

Страница 17: ...17 DECLARATION OF CONFORMITY...

Страница 18: ...18 COMPONENT PARTS...

Страница 19: ...ulator 14 Oil Scraper Ring 47 Straight Joints 15 Piston 48 Pressure Switch 16 Circlip 49 Safety Valve 17 Connecting Rod 50 Pressure Gauge 40 18 Crankcase 51 Pressure Gauge 50 19 Crank 52 Nut 20 Rubber...

Страница 20: ......

Отзывы: