Page 10
PBU
Operator's Manual (EN) - Propane Burnisher
EN
ENGLISH
8 Hour Time Weighted Average (OSHA Method)
1.5 % 750,000cf
Hours Operation
1
2
3
4
5
6
7
8
TWA (OSHA Method)
0 change/hr
5
14
27
46
69
96
128 164
1/2 change/hr
4
9
16
24
33
42
50
59
1 change/hr
3
7
11
16
20
25
29
34
2 change/hr
2
4
7
9
11
13
16
18
Based on the CO production rates shown above the TWA would not be exceeded in a
100 x 750 x 10 foot (empty) space after 8 hours with 2 air changes per hour.
(Assumes no additional CO
exposure during 8 hour time period)
Maintenance of Equipment
Warning: The proper maintenance of equipment is vital to safe operation. LPG engines are dependent on
engine tune up, and air filter replacement. CO concentration (production) skyrockets when the air to fuel ratio becomes
fuel rich. Follow the recommended Maintenance Schedule for the engine found in the Engine Operator/Owner Manual as
well as the Maintenance And Adjustments schedule found in the Propane Floor Equipment Operator’s Manual that were
supplied with the equipment.
CO Safety Equipment Available
•
Carb Guard automated emissions monitoring will shut down the engine when high emissions are detected.
•
Three-way type catalytic converter to scrub CO, Hydro Carbons (HC), and Nitrous Oxide (NOx) from the engine
exhaust providing the lowest possible emissions
•
High cubic feet per minute (CFM) fans (forced air mixing)
•
Digital combustion analyzers for tail pipe emissions monitoring
SPECIFICATIONS:
Model
2113E
2113ECL
2113BCAT 2117B
2117BCAT
2717B
2717BCAT
Part Number
08001B
08002B
08012B
08989B
08945B
08987B
08947B
Pad Size
21" (53 cm)
27" (68 cm)
Engine
13 hp Twin-V Kawasaki
17 hp Twin-V Kawasaki
Catalytic Muffler
No
No
Yes
No
Yes
No
Yes
Carb Gard
No
No
No
No
No
No
No
Clutch
None
Centrifugal
None
None
None
None
None
Pad Speed
2100 RPM
1500 RPM
Propane Tank
20 lb. (9.1 kg) Capacity, 80% Safety fill
Auto Fuel Shutoff
Yes
Low Oil Shutdown
Yes
Hour Meter
Yes
Sound Level
87 - 89 dB(A)
Productivity Rate
25,000 ft
2
/hr (2,322 m
2
/hr)
33,000 ft
2
/hr (3,066 m
2
/hr)
Agency Approvals
EPA plus UL Approved Propane Components
CARB Certified
No
No
Yes
No
Yes
No
Yes
(California Air Resource Board)
Weight
195 lbs.
198 lbs.
208 lbs.
220 lbs.
223 lbs.
242 lbs.
245 lbs.
Dimensions:
Length
51.5" (131.8 cm)
59" (149.9 cm)
Widith
23.3" (59 cm)
29.3" (74.4 cm)
Height
43" (109.2 cm)
43" (109.2 cm)
Warranty
2 YearS Parts & Labor
Содержание 08001B
Страница 45: ...Page 44 PBU Operator s Manual Propane Burnisher NOTES ...
Страница 51: ...Page 50 PBU Operator s Manual Propane Burnisher 17 HP Engine Assembly 7 08 KAWASAKI V Twin ...
Страница 60: ...PBU Operator s Manual Propane Burnisher Page 59 Electrical Schematic 120V A C System 7 08 ...
Страница 63: ......