120 VOLT MACHINES

Instructions for connection to the power

supply and the electrical ground.

This product must be grounded.  If it should
malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the
risk of electrical shock.  This product is equipped
with a cord having an equipment-grounding conductor
and grounding plug.  The plug must be inserted into
an appropriate oulet that is properly installed and
grounded in accordance with all local codes and
ordinances.

WARNING:

Improper connection of the

equipment-grounding conductor can
result in a risk of electric shock.  Check
with a qualified electrician or service
person if you are in doubt as to whether
the outlet is properly grounded.  Do not
modify the plug provided with the
product. If it will not fit the outlet, have a
proper outlet installed by a qualified
electrician.

This product is for use on a nominal 120 volt circuit
and has a grounding attachment plug that looks like
the plug illustrated in Figure 1.  Make sure that the
product is connected to an outlet having the same
configuration as the plug.  No adaptor should be
used with this product.

WARNING:  To prevent possible electric
shock, protect the machine from rain.
Keep the  machine in a dry building.

WARNING:  To prevent possible electric
shock, always use a 3-wire electrical
system connected to the electrical
ground.  For maximum protection
against  electrical shock, use a  circuit
that is protected by a ground fault circuit
interrupter.  Consult your electrical
contractor.

WARNING:  Do not cut, remove or break
the ground pin.  If the outlet does not fit
the plug, consult your electrical contrac
tor.

WARNING:  Have worn, cut or damaged
cords replaced by an authorized service
person.

EXTENSION CORDS

Use only an approved extension cord with three
conductors, a plug with three terminals, and a
connector body with three holes.  The machine has a
power cord with wire size 14 AWG.

WARNING:  If you use an extension
cord, use an extension cord with
minimum wire size 12 AWG.  Do not use
an extension cord longer than 50 feet.
Do not join two extension cords.

Figure 1

GROUNDED
OUTLET

GROUNDING
                PIN

GROUNDED
OUTLET BOX

Содержание 01193B

Страница 1: ...oyouortootherpersonnel damagetothemachineortootherproperty could occur as well You must have training in the operation of this machine before using it If your operator s cannot read English have this...

Страница 2: ...ion Chart 4 120VoltInstructionsforElectricalConnection 5 AbouttheMachine 6 How to Prepare Machine for Operation 6 How to Operate the Machine 7 Care and Maintenance 8 How to Correct Problems in the Mac...

Страница 3: ...perate this machine until it is completely assembled Inspect the machine carefully before operation DANGER Electrocution could occur if maintenance and repairs are performed on a unit that is not disc...

Страница 4: ...scrubbing FEATURES AND SPECIFICATIONS CAUTION Topreventseriousdamagetothefloorsurface makesurethemachineisalwaysmovingforward or backward when the pad is in contact with the floor Specifications OPERA...

Страница 5: ...achment plug that looks like the plug illustrated in Figure 1 Make sure that the product is connected to an outlet having the same configuration as the plug No adaptor should be used with this product...

Страница 6: ...the Pads WARNING Always remove the electrical plug from the electrical outlet before installing or changing the pad The pad driver assembly is on the bottom underside of the machine The pad holder ho...

Страница 7: ...osition and the power cable plugged into the proper outlet depress the interlock button 1 and squeeze the levers beneath the handle grips 2 See figure 3 3 Asthemotorreachesfullspeed 1 2seconds bring t...

Страница 8: ...detergent rinsing and hanging up to dry The pad driver spindle bearings should be re lubricated onceayear Donotoverlubricate Allowgreasetoenter bearingsslowly NOTE Do not store the machine resting on...

Страница 9: ...replace it The main switch is defective Contact an authorized service person The circuit breaker is defective Contact an authorized service person The machine is noisy The motor is defective Return t...

Страница 10: ...Page 10 CLARKE TECHNOLOGY Operator s Manual Ultra Speed Burnisher 1700 NOTES...

Страница 11: ...CLARKE TECHNOLOGY Operator s Manual Ultra Speed Burnisher 1700 Page 11 Section II Parts and Service Manual 70127B Ultra Speed Burnisher 1700...

Страница 12: ...has an indicator light that illuminates when the brushes are worn The commutator must be inspected each time the brushes are changed After the brushes have been replaced two times have the commutator...

Страница 13: ...brush and lead Install the screw 2 Use a hook to pull the spring out of the way Install the brush into the slot in the same position as the original brush the shunt wire on the brush should be located...

Страница 14: ...1 Page 14 CLARKE TECHNOLOGY Operator s Manual Ultra Speed Burnisher 1700 35 36 37 39 41 40 42 43 38 37 44 45 1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19 19 20 21 22 23 24 12 18 25 12 26 31 27 28 29...

Страница 15: ...Locknut 1 56 77378A Label ClarkeTechnology 2 57K 30185A Baffle 1 Ref Part No Description Qty 1 50774A Knob 2 2 170860 Washer Flat 12 3 62423A Clamp 1 4 49310A Wire 1 5 32369A Cover gray 1 32369B Cover...

Страница 16: ...CLARKE TECHNOLOGY Ultra Speed Burnisher 1700 Electrical Schematic 120Volts 11 00 Page 16 CLARKE TECHNOLOGY Operator s Manual Ultra Speed Burnisher 1700...

Страница 17: ...057A Stator Frame 1 12 902547 Bearing Upper 1 13 50136A Armature 120V 1 14 915044 Key 1 15 902550 Bearing Lower 1 16 40405AK Bottom End Plate 1 17 980076 Wave Washer 1 18 55646A Cord Assembly 1 19 596...

Страница 18: ...NOTES...

Страница 19: ...orway Bjornerudveien 24 N 1266 47 2275 1770 CLARKETECHNOLOGY AMERICAN SANDERS TECHNOLOGY A L COOK TECHNOLOGY Customer Service Headquarters and Factory 2100 Highway 265 Springdale Arkansas 72764 501 75...

Страница 20: ...Operations Department 2100 Highway 265 Springdale Arkansas 72764 for the nearest authorized Clarke Technology repair location Only these locations are authorized to make repairs to the product under...

Отзывы: