background image

Illuminators are powered by Power over the Ethernet (PoE) via a network cable 

connector to a PoE IEEE802at compliant switch.

The power consumption of the illuminators comply with PoE IEEE802at.

These illuminators are not supplied with a power cord. Instead, they are supplied with a 

1m long network cable. At the end of the network cable is a female RJ45 Cat5e compliant 

connector with an IP68 rated cover.

The IP68 rated cover is supplied with the illuminator. Follow the instructions supplied with 

the connector on how to attached if to the male Cat5e network cable.

ENSURE THAT THE IP68 RATED COVER IS CORRECTLY FITTED AND ATTACHED 

TO THE NETWORK CABLE. IF THIS IS NOT FITTED CORRECTLY MOISTURE CAN 

GET INTO THE CONNECTOR AND MAY CAUSE THE UNIT TO MALFUNCTION. THIS 

WOULD VOID THE WARRANTY ON THE PRODUCT.

Recommended PSU

Any IEEE802.3at compliant switch or injector.

Power supply should be approved to relevant EN Safety standards. 

Power Supply should be used with devices to protect against short circuits and overload.

External circuits used for interfacing with the illuminator (Camera Day/Night switching 

and Telemetry) should be reinforced/double insulated from mains.

This product complies with the European Directive 2014/30/EU Electromagnetic 
Compatibility and 2014/35/EU Low Voltage Directive by meeting the following standards: 

  

  

This symbol on the product means that the electrical and/or electronic equipment 

to which it relates should be disposed of at the end of life separately from domestic 

household waste.

There are separate collection systems for recycling in the EU. For more information 
please contact the Local Authority or supplier of the product

.

Photocell

The photocell is designed to automatically switch the lamps on at dusk and turn off at 

dawn. A high degree of hysteresis is incorporated to void on/off switching in marginal 

conditions. The unit is factory set at approximately 30 Lux On and 70 Lux Off, but can be 

adjusted.

Trouble Shooting

Ensure all tests are undertaken by a qualified, trained engineer and ensure safe working 

practices are followed at all times.

Step 1: Basics

• 

Check power connection

• 

Ensure PoE+ specification

• 

Check the photocell is working - cover photocell ,light should turn on

• 

Ensure power supply is suitably rated to product - check the specifications

Step 2: Set up Camera, lens and Illumination

• 

Check alignment of lamp

• 

Check camera lens- fully open at night and set correctly

• 

Check model number to performance specification to ensure required distance is 

achievable

Step 3: Call for further assistance

If the lamp is still not delivering the required performance, please contact Technical 

Support for further assistance

Note down:

• 

Model number and serial number of illuminator

• 

Camera make and model

• 

Lens make and model

      

Safety Warning

• 

When the lamp is running, it is hot to touch. before touching switch off the illuminator 

and allow to cool for a minimum of 10 minutes.

• 

The illuminator should be positioned so that prolonged starring into the illuminator at a 

distance closed than 1m is not expected.

• 

The light source of this illuminator is not replaceable, when the light source reaches its 

end of life the whole illuminator should be replaced.

• 

If the flexible power cord of the illuminator is damaged it should be exclusively replaced 

by an authorised service agent.

• 

This equipment is not suitable for use in locations where children are likely to be 

Factory Default Settings

When using the system for the first time, or if a factory reset has been made, the follow-

ing settings are used.

Product IP number:

 192.168.0.10

Subnet mask: 

255.255.255.0

Default router:

 192.168.0.1

Login

1. Open a web browser.

2. In the address field, type in the selected unit IP-address. 

3. The user interface login page is shown.

4. Create your username and password.

User manual can be downloaded from our website at 

www.gjd.co.uk

Pressure relief valve

IM Ethernet cable with 

IP68 connector

LED indicator

Reset

CE-EMC

EN55032

EN55024

EN 61547

EN 55015

EN 62493

EN 50130-4

(IT Immunity) 

(IT Immunity) 

(Lighting-Immunity)

(Lighting-Emission)

(Lighting -EMF) 

(Alarm-EMC)

CE-LVD

EN 60598-1

EN 60598-2-1

(Luminaires-General)

(Luminaires)

Safety

EN 62471 Risk 

group 2

(LED safety)

Environmental

IEC/EN 60529

EN50130-5 

IP66

(Alarm-environmental)

USA

FCC, Class B

AUS

RCM (AS/NZS CISPR 22 Class B)

RoHS:

Restriction of Hazardous Substances European directive 

202/95/EC

Certifications

WEEE:

Waste Electrical & Electronic Equipment European directive 

202/96/EC

POWER AND CONTROL CABLE CONNECTIONS

CLARIUS IP

CERTIFICATIONS

Отзывы: