![Clarion UNGO MS5500 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/clarion/ungo-ms5500/ungo-ms5500_install-manual_2612690021.webp)
MS5500 Installation Manual - Page 17
Programmable System Parameters
1.
Ignition Controlled Door Locking.
Selects whether or not the system automatically locks
the doors when the ignition is turned on. When selected, the Ignition Controlled Door
Locking feature will automatically lock the doors 10 seconds after the ignition key is turned
on.
To prevent the keys from being locked inside the vehicle when Ignition Controlled Door
Locking is on:
• The system will not lock the doors if any door is open when the ignition is turned on.
• The system will not lock the doors if any door is opened during the 10 second
countdown.
2.
Ignition Controlled Door Unlocking.
Selects whether or not the system automatically
unlocks the doors when the ignition is turned off. When selected, the Ignition Controlled
Door Unlocking feature will automatically unlock the doors when the ignition key is turned
off.
3.
Logic Sensor II - Warn Away Level
. Allows you to set the level of the Logic Sensor II’s
Warn Away sensitivity. When
High
is selected, a lighter impact will produce a warning chirp,
while the
Low
setting requires a stronger impact.
4.
Audible Tamper Alert Report.
When Audible Tamper Alert is selected, the siren will chirp to
indicate which zone had triggered the system, upon disarming.
If the system was triggered, the siren will emit one long chirp, followed by a series of short
chirps indicating the violated zone.
no chirp = ignition
1 chirp = door
Step
1
2
3
4
5
6
7
8
9
10
11
12
Function
Ignition Controlled Door Locking
Ignition Controlled Door Unlocking
Logic Sensor II Warn Away Level
Audible Tamper Alert Report
Door Unlock Pulse
Auto Rearm
Entry Delay for Passive Arming
Trunk Bypass
Illuminated Exit
Auxiliary Function 2 output
Logic Sensor Defeat
Transmitter Operating Mode
solid*
ON
ON
High
audible
single pulse
OFF
no delay
OFF
ON
momentary
OFF
Standard
flashing
(quickly)
OFF
OFF
Low
LED only
double pulse
ON
10 seconds
ON
OFF
latched
Aux 1
Convenience
flashing
(slowly)
30 seconds
Aux 2
Driver Door
Priority
Status LED
Button 2
Button 1
* default setting
installation_MS5500.qxd 12/6/99 11:59 AM Page 17
Содержание UNGO MS5500
Страница 1: ...installation_MS5500 qxd 12 6 99 11 59 AM Page 1 ...
Страница 2: ...installation_MS5500 qxd 12 6 99 11 59 AM Page 2 ...
Страница 4: ...installation_MS5500 qxd 12 6 99 11 59 AM Page 4 ...
Страница 30: ...Page 26 MS5500 Installation Manual Notes installation_MS5500 qxd 12 6 99 11 59 AM Page 26 ...
Страница 31: ...MS5500 Installation Manual Page 27 installation_MS5500 qxd 12 6 99 11 59 AM Page 27 ...