34
Filter Maintenance
Some water may drip from the
fi lter head (socket) during re-
placement. Keep a towel handy to
dry up any drips.
Warning: If the Zip HydroTap
is switched off for a long
period of time (e.g. More
than a weekend), run water
through the chilled water
outlet for at least 5 minutes
before consumption.
1
1
2
2
To change the Filter: (See also section B)
1. Open the door of the under sink unit.
2. Relieve system pressure via the fi lter fl ush stop cock, a quick
open and close will do. Use the bucket to catch the discharge.
3. Grasp fi lter cartridge and rotate the cartridge a quarter turn to
the left, then gently pull down.
4.
Caution:
a small amount of water will drip as the cartridge is
removed.
5. Do not tilt the cartridge as water may spill from it if tilted.
6. Unpack replacement cartridge and remove sanitary cap, write
today’s date where shown on the label.
7. Avoid touching the fi lter O-rings and fi lter opening as this may
cause bacterial contamination of the cartridge.
8. Moisten the O-rings with water, align the front cartridge label
to the left (as shown in the diagram for fi lter cartridge replace-
ment), and push the new cartridge into the fi lter head.
9. Turn the cartridge a quarter turn to the right until the cartridge
comes to complete stop and is locked into position, with the
front label facing forward.
10. Initiate the fi lter fl ush programme by scrolling through the menu
screen (See section B I).
11. Close the door to secure the appliance.
12. Adjust the fi lter settings as described in section B.
13. Dispose of the used fi lter correctly.