35
LCD Screen Operation - Section B
II. Temperature Settings
COLD/HOT SETPOINT
12:12 PM
Boiling Set Point
Chill Set Point
3-6
°C
98
°C
Tank Flush
The tanks must be rinsed during
initial commissioning and after a
long period of non-use.
Start the rinsing process by
tapping on the green arrow and
follow the instructions on the
display.
Hot water
Standard setpoint: 98 °C
Setpoint range: 68 - 100 °C.
Operation: Within 1 - 2 °C of the
setpoint.
Chilled water / Sparkling water
To ensure the best possible CO
2
binding to the water for sparkling
water, the temperature is fi xed at optimal values and cannot be
changed.
This is where the water tempera-
tures are set for operation. Boiling
point calibration is recommended
for every change of location and
especially for locations at high
altitudes.
During the rinsing process, the tank contents must be emptied
several times through the tap. If the spout of your tap is above a
sink or a draining board with a drain, you can activate the automatic
dispense for this.
Note
: When the automatic tap is active, water will fl ow out of the
tap several times without warning.
12:12
TANK FLUSH
Hot Tank
Cycle 1/2
98.0 °C
Run:
Auto
Dispense
Note
: The fl ow rate of boiling water is aff ected by a higher tem-
perature setting. At a setpoint of 98 °C, up to 6 % less energy is
consumed in standby mode than at 100 °C.
When setting temperatures close to boiling point, the pump is at risk
of cavitation. This is indicated by a warning symbol.