8. Operation

Performance monitoring

In the top row of the display, various information can be displayed 
permanently.

If you press the info button 

 once, the name of the currently selec-

ted monitor is displayed as scrolling text. To continue to the next 
monitor, press the info button 

 a second time while the scrolling 

text is visible. The name of the monitor will appear as scrolling text.

After the scrolling text, the value of the currently selected parameter 
will be displayed permanently in the top row of the display.

Individual parameter as follows:

CLAGE (or Clock, if enabled)

This is the normal display mode without an activated Energy and 
Status Monitor. If the clock was enabled in the Setup menu, it is only 
shown in normal display mode.

Note:
The menu items “Power“, “Flow“, “Temp In“, “Temp Out“ and “Costs 
per hour“ are explained in the chapter “Info Menu“.

Energy consumption since last use (Energy last tapping)

Energy consumption since last use in Wh or kWh.

Water consumption since last use (Water volume last tapping)

Display the amount of water used since last use in litres.

Total energy

Display of the total accumulated energy consumption in kWh.

Total water consumtion

Indication of the total water consumption in litres.

Note: The values are for information only and are not 
suitable for billing purposes.

Menu item order of 
“Energy Efficiency Monitor“:

C LO C K

P O W E R

F LO W

T E M P   I N

T E M P   O U T

E N E R G Y   L A S T  TA P P I N G

WAT E R   V O LU M E   L A S T 

TA P P I N G

T O TA L   E N E R G Y

T O TA L   WAT E R   V O LU M E

Содержание Zip DSX ELECTRONIC MPS 27940

Страница 1: ...Electronically controlled instantaneous water heater DSX 27940 50 C models Instructions for the user For 50 C models the appliance delivers water not exceeding 50 C in accordance with AS3498...

Страница 2: ...1099 Servomotor with electronic 2 1 5 801099 Flow sensor 6 801101 Non return valve 7 DSX hood 8 Bottom part 9 Wall bracket 10 DSX connecting pipe 11 801102 PCB cover 2 1 12 Control panel support 13 Co...

Страница 3: ...riate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance...

Страница 4: ...n case of maintenance the appliance must be vented correctly in accordance with the instructions in this manual Do not remove the front cover under any circumstances before switching off the mains ele...

Страница 5: ...Pa 10bar Heating system Bare wire heating system IES Required spec water resistance 15 C 1100 cm Spec electrical conductivity 90mS m Inlet temperature 70 C Flow rate to switch on 2 5 l min Pressure lo...

Страница 6: ...6 Instructions for user 9120 34315 DSX 801049 November 2012 v1 00 6 Typical installations...

Страница 7: ...Duschkabine ca 1950 466 363 56 100 170 Alternativer Kabeleingang 231 550 upper edge of the shower cabin approx 1950 lower edge of the appliance min 10 recommended approx 1200 upper edge of the wash b...

Страница 8: ...sed or decreased in increments of 1 C by briefly pressing the up arrow and down arrow function keys Depressing the function key for a longer time changes the tempera ture continuously The temperature...

Страница 9: ...activated or deactivated Working time Indication of total operating time of the heating given in seconds minutes days years Standby time Indication of the operating time since latest connection of the...

Страница 10: ...to be adjusted Press the setup key and the info key simultaneously for at least 3 sec onds to call up the setup menu the display confirms by setup Using the arrow keys and to select the available mode...

Страница 11: ...settings can be done Setting options h hours min minutes s seconds The info key selects the clock parameter to be changed h min or s The arrow keys and changes the set value shown Pressing the setup k...

Страница 12: ...ory reset via key countdown not possible param eters can be seen but not be modified in setup menu 2 same as 1 additionally the setup menu cannot be opened 3 same as 2 additionally nominal value memor...

Страница 13: ...display mode without an activated Energy and Status Monitor If the clock was enabled in the Setup menu it is only shown in normal display mode Note The menu items Power Flow Temp In Temp Out and Cost...

Страница 14: ...ng excessively hot water Also any cold water added is not controlled by the electronic circuitry meaning that precise temperature control can no longer be guaranteed when supplying more than one outle...

Страница 15: ...ircuit breaker tripped Reset circuit breaker STCO tripped Contact Zip Service to reset STCO Display flashes error symbol screwdriver Control system has switched off Switch power supply off and on If t...

Страница 16: ...16 Instructions for user 9120 34315 DSX 801049 November 2012 v1 00 11 Notes...

Страница 17: ...17 Instructions for user 9120 34315 DSX 801049 November 2012 v1 00 11 Notes...

Страница 18: ...1 A2 B1 B2 C1 C2 D1 D2 Press 3 Secs Setup menu 2 8 4 7 5 3 6 9 1 Display flashes Press 3 secs Head Office Zip Heaters Aust Pty Ltd ABN 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal L...

Отзывы: