23
CLAGE
• Plastic surfaces and fittings may only be wiped with a damp cloth. Never use abra-
sive cleaning agents or solvents.
• The electrical and plumbing components should be inspected by an approved pro-
fessional every two years to ensure proper functioning and operational safety at all
times.
11. Cleaning and maintenance
10. Reset safety thermal cut-out
Attention! These works must only be conducted by an authorised professional.
Note: You must not reset the safety thermal cut out if it was triggered while the stor-
age water heater was empty. In this case the thermostat and the safety thermal cut out
need to be replaced. Please contact the CLAGE customer service for this purpose.
1. Pull out the main plug.
2. Remove the temperature selector by pulling it forward.
3. Loosen the screw which is located behind the temperature selector.
4. Remove the hood by pulling it forward carefully.
5. Reset the safety thermal cut out by triggering the reset button with a screwdriver.
6. Replace the hood carefully. When mounting the hood ensure that no cables are
pinched or clamped!
7. Replace the screw and tighten it.
8. Push the temperature selector back onto the shaft.
9. Start up the storage water heater according to the chapter “Initial operation“.