background image

6

Instruc

tions f

or installer - 9120-15004 - MCX - 801053 - M

a

rch 2013 v1.01

5. Typical installations

Angle valve G 1/2“

Flow controller

MCX 3/4 :            CSP 3 

MCX 6 : 

          CSP 6

Top edge of wash basin appr

o

x.. 850

Dimensions in mm

Electrical connection with mains 
power cable 
(shorten if necessary)

Axis wall bracket appr

o

x. 520

C

able entr

y appr

o

x. 553

Angle valv

e appr

o

x. 550 

Vented installation with 
special open outlet tap

Содержание MCX 27300

Страница 1: ...Electronically controlled instantaneous water heater MCX 27300 27400 and 27600 models Installation instructions These appliances deliver water not exceeding 50 C in accordance with AS3498...

Страница 2: ...er 5 MCX water connector set with two water connectors and seals mounted and greased fastening safety earthing terminal and filter Pos Part No Description 6 MCX complete fixing set wall bracket with s...

Страница 3: ...ent which could other wise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for i...

Страница 4: ...in case of maintenance the appliance must be vented correctly in accordance with the instructions in this manual Do not remove the front cover under any circumstances before switching off the mains el...

Страница 5: ...in 2 5 l min 3 3 l min Maximum temperature increase at rated power and a flow rate of 1 2 0 l min 25 K 31 K 41 K 2 5 l min 20 K 25 K 33 K 3 0 l min 17 K 21 K 27 K 3 5 l min 14 K 18 K 23 K 4 0 l min 12...

Страница 6: ...gle valve G1 2 Flow controller MCX3 4 CSP3 MCX6 CSP6 Top edge of wash basin approx 850 Dimensions in mm Electrical connection with mains power cable shorten if necessary Axis wall bracket approx 520 C...

Страница 7: ...allation closed outlet with tap for pressurised appliances Dimensions in mm Angle valve approx 550 Top edge of wash basin approx 850 Axis wall bracket approx 520 Cable entry approx 553 MCX3 4 CSP3 MCX...

Страница 8: ...AS NZS 3500 as well as those of the local electricity and water supply companies The specifications on the rating plate The rating plate is located under the appliance s cover See Section 10 on remov...

Страница 9: ...intenance work a shut off valve should be installed in the supply line The appliance must be accessible for maintenance work The hot water pipes must be thermally insulated See Section 4 for the speci...

Страница 10: ...hanical pressure on the appliance by applying a spanner on the flats of the inlet and outlet connections when tightening the pipe connectors Fig 3 2 Once the water connections have been made check for...

Страница 11: ...ith current Australian regulations and any Local Authority requirements IMPORTANT The appliance must be installed according to the specification on the rating plate and the technical specifications En...

Страница 12: ...der the appliance s cover 9 Flow rate adjustment Removing the cover The rating plate and the adjusting screw for the flow rate is located under the cover 1 Push the cover on the corrugated side toward...

Страница 13: ...w rate Turning the adjusting screw counter clockwise increases the flow rate thus reducing the possible outlet temperature 10 Removing the appliance from the wall bracket To remove the appliance from...

Страница 14: ...ufficient Increase the water flow to the appliance Slow water flow rate at outlet Flow controller not fitted Fit the correct flow controller see Section 6 or contact Zip Service Water pressure not suf...

Страница 15: ...15 Instructions for installer 9120 15004 MCX 801053 March 2013 v1 01 13 Notes...

Страница 16: ...cked Bag 80 Bankstown 1885 Australia Website www zipheaters com Facsimile 02 9796 3858 Telephone 02 9796 3100 Free Call 1 800 638 633 As Zip policy is one of continuous product improvement changes to...