CLAGE
19
EN
Model
DEX 12 ELECTRONIC MPS®
Energy efficiency class
A *
)
Article no.
34212
Power setting
8,8
12
Chosen capacity (Current) @ 220 V
8,0 kW (36,6 A)
10,5 kW (47,7 A)
@ 230 V
8,8 kW (38 A)
11,5 kW (50 A)
@ 240 V
9,6 kW (40 A)
12,5 kW (52,2 A)
Electrical connection
1/N/PE 220 V .. 230 V .. 240 V
Required cable size
10,0 mm
2
Hot water (l/min)
max. at ∆t = 28 K
4,5
5,9
1)
max. at ∆t = 38 K
3,3
4,3
Rated volume
0,4 l
Rated Pressure
1 MPa (10 bar)
Connecting type
pressure resistant / pressure less
Heating system
Bare wire heating system IES®
Required spec. water
resistance @ 15 °C
≥ 1300 Ωcm
Spec. electrical conductivity
≤ 77 mS/m
Inlet temperature
≤ 25 °C
Flow rate to switch on – max. flow rate
2,5 – 5,0 l/min
2)
Pressure loss
0,2 bar at 2,5 l/min 1,3 bar bat 9,0 l/min
3)
Temperature choice
20 °C – 55 °C
Water connection
G ½“
Weight (when filled with water)
3,70 kg
VDE class of protection
I
Type of protection / safety
IP25
*) The declaration complies with the EU regulation No 812/2013
1) Mixed water
2) Flow rate limited to achieve optimum temperature rise
3) Without flow regulator
3. Technical specifications
4. Dimensions
231
231
170
363
466
56
100
97
Dimensions in mm