![clage CDX 11-U Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/clage/cdx-11-u/cdx-11-u_installing-instructions-for-the-professional_2612127015.webp)
CLAGE
15
EN
Electrical connection
Check that the power supply is switched off prior to electrical connection!
Electrical connection with pre-installed power cable
The appliance is to be connected with the preinstalled power cable to a terminal box.
If necessary, use one of the three predetermined breaking points for the cable entry (at
the right, left or bottom).
7. Electrical connection
Only by a specialist!
Please observe:
• e.g. VDE 0100
• The installation must comply with current IEC and national local regulations or
any particular regulations, specified by the local electricity supply company
• The rating plate and technical specifications
• The appliance must be earthed!
Wiring diagram
2
1
4
5
3
1. Electronic circuitry
2. Heating element
3. Safety pressure cutout
4. Connecting terminal
5. Safety thermal cutout
• The appliance must be installed via a permanent connection. Heater must be
earthed! Maximum cable cross section: 6 mm
2
.
• The electric wiring should not be injured. After mounting, the wiring must not be
direct accessible.
• An allpole disconnecting device (e.g. via fuses) with a contact opening width of at
least 3 mm per pole should be provided at the installation end.
• To protect the appliance, a fuse element must be fitted with a tripping current com
mensurate with the nominal current of the appliance.
Structural prerequisites