background image

F I L O X S e r i e s F i l t e r

Installation Operation Maintenance Manual

FILOXWS1-3B APRIL 2011 \page 1

Installation
Operation
Maintenance
Manual

FILOX Filter
WS1TC Series Valve

Models

CF1044-3B

CF1248-3B

CF1354-3B

CF1465-3B

Содержание WS1TC Series

Страница 1: ...Series Filter Installation Operation Maintenance Manual FILOXWS1 3B APRIL 2011 page 1 Installation Operation Maintenance Manual FILOX Filter WS1TC Series Valve Models CF1044 3B CF1248 3B CF1354 3B CF1...

Страница 2: ...ater 7 5 1 4 Pipework 8 5 1 5 Water Supply Company Requirements 8 5 2 ELECTRICAL 8 6 0 ASSEMBLY INSTALLATION 9 6 1 MECHANICAL 9 6 1 1 Pipework 9 6 1 2 Drains and overflow connections 9 6 2 ASSEMBLY 10...

Страница 3: ...stribution system 5 4 2 1 2 REDUCER if required 6 FILOX MEDIA qty as specified 1 3 MISSING OR DAMAGED GOODS Immediately on receipt of the goods it is advisable to check that all items ordered have bee...

Страница 4: ...e operating parameters for FILOX make it suitable for a number of water types 3 2 System Management In order to remove accumulated deposits from the filter bed the water flow through the filter is rev...

Страница 5: ...have accumulated during the service cycle Fast Rinse This follows the backwash cycle and entails rinsing away any residual deposits from the media and re packing the media bed This is carried out down...

Страница 6: ...flows The total flow of water to drain depends on site conditions but will be at least the same as the service flow Preferably the drain should be level but no higher than 500mm above the filter valve...

Страница 7: ...y Requirements During backwash the accumulated debris and oxidised iron and manganese is flushed to drain Please contact your local Water Authority for advice on effluent issues if concerned with flow...

Страница 8: ...to accommodate the flow of water required making due allowance for the pressure drop between the filter and the point of discharge of treated water NOTE IF BRAZED OR SOLDERED FITTINGS ARE TO BE USED T...

Страница 9: ...e at most 50 full This is to allow rising space for the media during the backwashing cycle Once the vessel is filled immediately sweep up any spilled filter media Remove the cap from the riser tube an...

Страница 10: ...10 Connect the drain line to the outlet of the drain line flow controller on the valve Ensure that there is an air break in the drain at the same height as the valve to prevent negative pressure on th...

Страница 11: ...erienced engineer are not available following the steps outlined below will result in the system being properly commissioned 7 2 Setting the Time of Day Press Set Hour set the clock to the Closest Hou...

Страница 12: ...2011 page 12 7 3 Regeneration Programming All programming below is Factory set To enter Installer level press SET Hour Up for 3 seconds and then SET HOUR UP for 3 seconds Set to P 8 then press SET HOU...

Страница 13: ...vel 7 4 User Programming All programming below is Factory set To enter User level press SET HOUR UP for 3 seconds Set the Clock to the hour of regeneration using the up and down buttons after 12 an ar...

Страница 14: ...on motor and the timer motor 7 2 3 Next start a manual backwash by pressing the UP and DOWN button together for 3 sec or until the motor starts to turn 7 2 4 When the motor has stopped switch off the...

Страница 15: ...pletely automatic and should not require adjustment Weekly Check the treated water quality with a test kit Monthly Check raw water quality and record Compare with original quality and adjust frequency...

Страница 16: ...kwash If this does not free up the media the filter will need to be inspected and serviced by a competent engineer Backwash with chlorine solution to remove organic build up 9 2 POOR TREATED WATER QUA...

Страница 17: ...ram Check timer motor is running Check drive motor runs by manually initiating a backwash and listening for drive motor as it advances between cycles Replace if necessary 9 4 UNSATISFACTORY CAPACITY B...

Страница 18: ...0 WARRANTY AND SERVICE Your filter is covered by a parts warranty for a period of one year from installation or 14 months from purchase Consumable filter media is excluded from this warranty Should y...

Страница 19: ...ance Manual FILOXWS1 3B APRIL 2011 page 19 11 0 TECHNICAL DATA 11 1 PROCESS AND OPERATING DATA PARAMETER UNITS CF1044 3B CF1248 3B CF1354 3B CF1465 3B FLOW RATE M3 HR 0 9 1 35 1 8 2 3 BACKWASH FLOW M3...

Страница 20: ...r MAXIMUM OPERATING TEMPERATURE 45 0C HEADROOM Allow 100 mm greater than overall height MODEL CF1044 3B CF1248 3B CF1354 3B CF1465 3B VALVE FILTER VESSEL 1054 1248 1354 1465 HEIGHT MM 1607 1458 1601 1...

Страница 21: ...LOXWS1 3B APRIL 2011 page 21 12 0 SPARES LIST PART NO DESCRIPTION XCV3011 Piston WS1TC XFR1 Riser Tube c w 1 Dist XCV3005 Seal Spacer kit WS1TC XCV3107 01 Drive Motor 12v VDLFC3 3 4 Brass flow control...