The control valve with a water meter can be set for Demand Initiated Regeneration (DIR) only, Time Clock operation only or DIR and
Time Clock which ever comes
fi
rst, depending upon what settings are selected for Day Override and Gallon Capacity.
2
See Table 7.
If a control valve does not contain a meter, the valve can only act as a time clock, and day override should be set to any number and gallon
capacity should be set to off.
For DIR Softeners, there are two options for setting the Gallons Capacity. The Gallons Capacity is automatically calculated if set to AUTO.
Reserve Capacity is automatically estimated based on water usage if AUTO is used. The other option is to set the Gallons Capacity to a
speci
fi
c number. If a speci
fi
c number is set, reserve capacity is zero, unless the value is manually set (i.e. the
manufacturer intentionally sets the gallon capacity number below the calculated capacity of the system).
The control valve can also be set to regenerate immediately or at the next regeneration time by changing the Regeneration Time Option.
There are three choices for settings:
1. “NORMAL” means regeneration will occur at the preset regeneration time.
2. “on 0” means regeneration will occur when the gallons capacity reaches zero.
3. “ on 0” means the regeneration will occur at the preset regeneration time unless the gallons capacity reaches zero. If the
gallons capacity reaches zero the regeneration will begin 10 minutes after no water usage.
The user can initiate manual regeneration. The user has the option to request the manual regeneration at the delayed regeneration time or to
have the regeneration occur immediately:
1. Pressing and release REGEN. “Regen Today” will
fl
ash on the display and the regeneration will occur at the delayed regeneration
time. The user can cancel the request by pressing and releasing REGEN. This method of manually initiating regeneration is not
allowed when the system is set to “on 0,” i.e. immediately regenerate when the gallon capacity reaches zero.
2. Pressing and holding REGEN for approximately 3 seconds will immediately start the regeneration. The user cannot cancel this
request, except by resetting the control by pressing NEXT and REGEN simultaneously for 3 seconds.
A unique feature of this control valve is the ability to display actual water usage for the last 63 days. The values are initially stored as
“----”. This means the value is unknown. As days pass values are stored as “0” for no
fl
ow or the actual number of gallons. The counting
of the gallons starts at the regeneration time. If no regeneration time can be set (i.e. when the valve is set for immediate regeneration) the
counting of gallons starts at 12 a.m. Day 1 is yesterday, day 2 the day before yesterday, etc.
Another unique feature is that the valve automatically calculates a reserve capacity when set up as a softener with “Gallons
Capacity” set to “AUTO” and the “Regeneration Time Option” set to “Normal” or “ on 0”. The actual reserve capacity is
compared to the gallons capacity remaining immediately prior to the preset regeneration time. A regeneration will occur if the actual
reserve capacity is less than the gallons capacity remaining. The actual reserve capacity is calculated by using the estimated reserve
capacity and adjusting it up or down for actual usage.
The estimated reserve capacity for a given day of the week is the maximum value stored for the last three non-trivial water usages (i.e.
more than 20 gallons/day) in seven day intervals.
3
Day Override and Gallon Capacity cannot be set to “oFF” at the same time.
2
See Installer Display Settings Step 3I, OEM Softener Setup Step 7S and OEM Filter Setup Step 6F for explanations of Day
Override and Gallon Capacity.
DIR
Time
Clock
Reserve Capacity
Softener
Filter
Settings
3
Regenerant
Backwash
Only
Day
Override
Gallon
Capacity
Yes
Automatically calculated
Yes
Off
Auto
Yes
If desired enter a value less
than estimated capacity
Yes
Yes
Yes
Off
Any
Number
Yes
Yes
Automatically calculated
Yes
Any Number
Auto
Yes
Yes
If desired enter a value less
than estimated capacity
Yes
Yes
Yes
Any Number
Any
number
Yes
None
Yes
Yes
Yes
Any Number
Off
Table 7
DIR/Time Clock Options