background image

 

[SM-P00049-A]

 

17

 

PRODUCT 

 

 

 

 

M4GB4

 

Internal pilot

 

R1/2 female thread type

15

) 

Supply and exhaust block

Q

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

L=(29xn)+213 

2

2

7

.6

 :

 3

-

p

o

si

ti

o

n

 

1

6

9

.5

 :

 S

in

gl

e

 s

o

le

n

o

id

 

2

0

7

.1

 :

 D

o

u

b

le

 s

o

le

n

o

id

 

1

3

7

.7

 

L1=(29xn)+133 

179 

29(pitch) 

59 

Mounting hole 
4-φ9 

1

3

1

.9

(M

an

u

al

 o

ve

rr

id

p

o

si

ti

o

n)

 

1

2

1

.6

(M

an

u

al

 o

ve

rr

id

p

o

si

ti

o

n)

 

1

1

1

.2

 (

M

an

u

al

 o

ve

rr

id

e

 p

o

si

ti

o

n

40 

4

9

.5

 

3

3

 

3

1

.6

 

2

7

 

Rc1/2 
2(B) port 

Rc1/2 
4(A) port 

15 

1

8

.9

 

1

0

3

.7

 

1

1

0

.3

 

6

6

 

L4=(29xn)+183 

1

5

.5

 

171.5 

16.5 

2-Rc1/2 
3/5(R) port 

2-Rc1/2 
1(P) port 

29 (pitch) 

Содержание M4GA4-T6G1

Страница 1: ...PE SERIAL TRANSMISSION TYPE SERIAL TRANSMISSION TYPE SERIAL TRANSMISSION TYPE M4G 4 M4G 4 M4G 4 M4G 4 T6G1 T6G1 T6G1 T6G1 Please read this instruction manual care fully before using this product parti...

Страница 2: ...read this read this read this instruction instruction instruction instruction manual carefully for manual carefully for manual carefully for manual carefully for proper operation proper operation pro...

Страница 3: ...ecifications 5 1 4 Outside view of valve 9 1 5 Slave station for valve 19 2 CAUTION 22 3 OPERATION 3 1 Switch setting 22 3 2 Correspondence between Output Nos and internal connector Nos 25 3 3 Corresp...

Страница 4: ...programs that control these devices installed away from the master system has the following features 1 To a single master station the CC Link system allows the connection of up to 64 remote I O statio...

Страница 5: ...tation Station controlling remote I O stations remote device stations and local stations Remote I O station Remote station that handles ON OFF data only Remote device station Remote station that handl...

Страница 6: ...e1 Not required Degree of protection Dust proof Vibration shock m s2 50 or less 300 or less Atmosphere Use in the environment containing corrosive gas is not permissible Note 1 Use the turbine oil Cla...

Страница 7: ...0 38 7 1 0 15 Rc3 8 G3 8 NPT3 8 3 position PAB connection 6 0 0 37 6 8 0 13 2 position 8 3 0 23 9 0 0 21 All ports closed 7 4 0 15 8 8 0 19 ABR connection 7 5 0 15 9 5 0 21 M4GB4 Rc1 2 G1 2 NPT1 2 3 p...

Страница 8: ...on speed In the case of multi drop connection Ver 1 10 B RATE Transmission Speed Interstation Cable Length Total Cable Extension 4 10Mbps 100m 3 5Mbps 160m 2 2 5Mbps 400m 1 625kbps 900m 0 156kbps 0 2m...

Страница 9: ...xed use of cables only for CC Link and high performance cables only for CC Link is allowed 3 Slave station specification Item Specification Communication object CC Link Ver1 10 Note 1 Power supply vol...

Страница 10: ...L1 26 5xn 129 5 144 5 26 5 pitch 24 5 Push in joint 4 A port Rc3 8 4 A port Mounting hole 4 6 6 Push in joint 2 B port Rc3 8 2 B port 2 Rc1 2 5 R port 2 Rc1 2 1 P port 2 Rc1 2 3 R port 17 35 35 19 5...

Страница 11: ...joint 4 A port Rc3 8 4 A port Mounting hole 4 9 Push in joint 2 B port Rc3 8 2 B port 2 Rc1 2 5 R port 2 Rc1 2 1 P port 2 Rc1 2 3 R port 21 35 3 36 6 29 4 2 Rc1 8 12 14 PA port 29 39 1 51 9 131 9 Manu...

Страница 12: ...id 137 7 L1 26 5xn 135 5 179 26 5 pitch 59 Push in joint 2 B port Rc3 8 2 B port 131 9 Manual override position 121 6 Manual override position 111 2 Manual override position 40 49 5 33 31 6 117 2 Rc3...

Страница 13: ...5 pitch 59 Push in joint 4 A port 2 Rc1 8 82 84 PR port Mounting hole 4 9 Rc3 8 2 B port 131 9 Manual override position 121 6 Manual override position 111 2 Manual override position 40 49 5 33 31 6 1...

Страница 14: ...noid 137 7 143 26 5 pitch Push in joint 4 A port 2 Rc3 8 5 R port Mounting hole 4 6 6 Push in joint 2 B port 131 9 Manual override position 121 6 Manual override position 111 2 Manual override positio...

Страница 15: ...le solenoid 137 7 149 29 pitch Mounting hole 4 9 Rc1 2 4 A port 131 9 Manual override position 121 6 Manual override position 111 2 Manual override position 29 49 5 33 27 16 5 103 7 61 141 5 L1 29xn 1...

Страница 16: ...9 Mounting hole 4 9 2 Rc1 2 5 R port 2 Rc1 2 1 P port 2 Rc1 2 3 R port 21 35 3 43 8 29 4 2 Rc1 8 12 14 PA port 29 39 1 51 9 131 9 Manual override position 121 6 Manual override position 111 2 Manual o...

Страница 17: ...Double solenoid 137 7 L1 26 5xn 128 5 169 26 5 pitch 49 Mounting hole 4 6 6 131 9 Manual override position 121 6 Manual override position 111 2 Manual override position 33 48 36 27 4 22 Push in joint...

Страница 18: ...5 Single solenoid 207 1 Double solenoid 137 7 L1 29xn 133 179 29 pitch 59 Mounting hole 4 9 131 9 Manual override position 121 6 Manual override position 111 2 Manual override position 40 49 5 33 31...

Страница 19: ...1 29xn 133 179 29 pitch 59 Push in joint 2 B port 2 Rc1 8 12 14 PA port Mounting hole 4 9 131 9 Manual override position 121 6 Manual override position 111 2 Manual override position 40 49 5 33 31 6 2...

Страница 20: ...SM P00049 A 19 PRODUCT 1 5 Slave station for valve 1 Appearance 41 50 84 47 5 66...

Страница 21: ...he user specifies a value out of range when setting the station number or transfer rate Lit again when the user corrects the setting and reboots the system Blinks when the station number or transfer r...

Страница 22: ...ce Wiring connection to sta tion is accomplished through these terminal blocks Function of each terminal is printed on the face of station mounting device Choose 6 6mm wide or less of M3 crimp type te...

Страница 23: ...ring an error and specifying the end station Since different switches are used for different kinds of setup you must correctly identify the switch to be used Before changing the switch positions be su...

Страница 24: ...se the same station No 2 Transfer rate setting SW3 Set the transfer rate for communication between the master and slave stations Position Transfer rate 0 156kbps 1 625kbps 2 2 5Mbps 3 5Mbps 4 10Mbps B...

Страница 25: ...2 Additionally 130 terminating resistor 1 2W which is purchased on the gen eral market or supplied with the master station is connected to a position between the terminal blocks DA and DB of this slav...

Страница 26: ...and manifold solenoid correspond with each other as per tables posted below 2 Manifold block number is allocated from leftmost block toward right while holding piping port facing to you regardless th...

Страница 27: ...the Mitsubishi User s Manual CC Link system master local units Functions particular to this slave station unit are the specification of the state of output during an error and the declaration of the...

Страница 28: ...e name and specifications of the recommended cable in the table below Specifications Item Cable exclusively for CC Link High performance cable exclusively for CC Link Name FANC SB FANC SBH Manufacture...

Страница 29: ...uit for the solenoid valve system Moreover two separate power sources can be used to supply power independently to the slave station unit and the solenoid valve system The illustrations below are exam...

Страница 30: ...er power cables Since connecting the electric wires that were only twisted direct to the terminal strip may cause firing be sure to use a crimp terminal Connect the power supply always after checking...

Страница 31: ...has blown The ERR LED on the master station unit blinks to report an error Check the unit associated with the register that is ON one among SW0098 through SW009B Is any of the special master station l...

Страница 32: ...t Is the data cable properly con nected Y N N Y Is the L RUN LED lit Is the SD LED lit or blinking Is the transfer rate B RATE correctly set Y N N N Y Y Correct the power supply voltage The unit is fa...

Страница 33: ...setting switches without a duplicate N Correct the station number setting Turn the power OFF and then ON Y The unit is faulty The station number setting switches are faulty Y Done From previous page...

Страница 34: ...PAB connection Rc1 4 2 G1 4 2 NPT1 4 2 Rc3 8 G3 8 e Option NPT3 8 Rc1 2 2 none G1 2 2 External pilot NPT1 2 2 Coolant proof f Station number 2 M4GB4 only A B port filter integrated Supply spacer 2 st...

Отзывы: