[SM-P00121-A]
―
17
―
3
OPERATION
◆
N4G*R-T8D*2
(
32-point output specification
)
[Standard wiring]
When all valves mounted on the manifold are single-solenoid types:
Solenoid
output No.
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a 2a 3a 4a 5a 6a 7a 8a 9a 10a 11a 12a 13a 14a 15a 16a 17a 18a 19a 20a 21a 22a 23a 24a 25a 26a 27a 28a 29a 30a 31a 32a
When all valves mounted on the manifold are double-solenoid types:
Solenoid
output No.
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a 1b 2a 2b 3a 3b 4a 4b 5a 5b 6a 6b 7a 7b 8a 8b 9a 9b 10a 10b 11a 11b 12a 12b 13a 13b 14a 14b 15a 15b 16a 16b
When both single and double solenoids valves are mounted on the manifold (an example is shown above):
Solenoid
output No.
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a 2a 3a 3b 4a 4b 5a 6a 7a 7b 8a 9a 10a 10b 11a 11b 12a 13a 14a 14b 15a 15b 16a
[Double wiring]
(Note: “B” indicates a blank station)
When all valves mounted on the manifold are single-solenoid types:
Solenoid
output No.
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a
B
2a
B
3a
B
4a
B
5a
B
6a
B
7a
B
8a
B
9a
B
10a
B
11a
B
12a
B
13a
B
14a
B
15a
B
16a
B
When all valves mounted on the manifold are double-solenoid types:
Solenoid
output No.
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a 1b 2a 2b 3a 3b 4a 4b 5a 5b 6a 6b 7a 7b 8a 8b 9a 9b 10a 10b 11a 11b 12a 12b 13a 13b 14a 14b 15a 15b 16a 16b
When both single and double solenoids valves are mounted on the manifold (an example is shown above):
Solenoid
output No.
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a
B
2a
B
3a 3b 4a 4b 5a
B
6a
B
7a 7b 8a
B
9a
B
10a
B
11a 11b 12a 12b 13a
B
14a
B
15a 15b 16a
B
Note: The figure below is an
example of double-solenoid type
valves mounting 16 stations on the
manifold. There is no solenoid on
the b-side for single-solenoid type.
Manifold
No.
No.9
No.10
No.11
No.12
No.13
No.14
No.15
No.16
No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.8
A side
B side