FWD
Series
+HDG2IILFH3ODQW
2XML.RPDNL$LFKL
TEL
)$;
6DOHV$QG0DUNHWLQJ'LY 2XML.RPDNL$LFKL
TEL
)$;
2YHUVHDV6DOHV$GPLQLVWUDWLRQGSW 2XML.RPDNL$LFKL
TEL
)$;
2YHUVHDV%XVLQHVVGLY
7RN\R%UDQFK2IILFH
)%XQNDKRXVRX0HDPDPDWVXFKR
TEL
)$;
0LQDWRNX7RN\R
1DJR\D%UDQFK2IILFH
2XML.RPDNL$LFKL
TEL
)$;
2VDND%UDQFK2IILFH
7RVDERUL1LVKLNX2VDND
TEL
)$;
&$&
1
Term of warranty
:DUUDQW\3HULRGLVRQH\HDUIURPWKH¿UVWGHOLYHU\WRWKH
customer.
3
&RPSDWLELOLW\FRQ¿UPDWLRQ
In no
HYHQW VKDOO
CKD be
OLDEOH
for
PHUFKDQWDELOLW\
or
¿WQHVV
for a
SDUWLFXODU
purpose, notwithstanding any
GLVFORVXUH
to
CKD of the use to which the product is to be put.
2
Scope of warranty
In case any defect attributa
EO
e to CKD is found during the Warranty Period, CKD sha
OO
, at its own discretion, repair the defect or rep
O
ace the
r
HO
e
Y
ant product in who
O
e or in part, according to its own judgement.
Note that the fo
OO
owing fau
O
ts are exc
O
uded from the warranty term:
(1)
3URGXFWDEXVHPLVXVHFRQWUDU\WRFRQGLWLRQVHQYLURQPHQWUHFRPPHQGHGLQLWVFDWDORJVVSHFLILFDWLRQV
(2) Fai
O
ure caused by other than the de
O
i
Y
ered product
(3)
8VHRWKHUWKDQRULJLQDOGHVLJQSXUSRVHV
(4) Third-party repair/modification
)DLOXUHFDXVHGE\UHDVRQWKDWLVXQIRUHVHHDEOHZLWKWHFKQRORJ\SXWLQWRSUDFWLFDOXVHDWWKHWLPHRIGHOLYHU\
)DLOXUHDWWULEXWDEOHWRIRUFHPDMHXUH
,QQRHYHQWVKDOO&.'EHOLDEOHIRUEXVLQHVVLQWHUUXSWLRQVORVVRISURILWVSHUVRQDOLQMXU\FRVWVRIGHOD\RUIRUDQ\RWKHU
VSHFLDOLQGLUHFWLQFLGHQWDORUFRQVHTXHQWLDOORVVHVFRVWVRUGDPDJHV
'LVFODLPHU
Safety precautions
Be sure to read the instructions before use.
Refer also to the precautions of "General Purpose Valves(No. CB-03-1SA)".
WARNING
Design & Selection
:RUNLQJÀXLG
<RXFDQQRWXVHDÀXLGRWKHUWKDQZDWHU
Working environment
Do not use the product where the product is exposed to direct-sunlight or may come in contact with water or oil.
Can not be used outdoors.
CAUTION
Design & Selection
Design for Safety
/HDNDJHFXUUHQWIURPRWKHUÀXLGFRQWUROFRPSRQHQWV
When using a programmable controller, etc., with CR
circuits to absorb the surge voltage generated by switch-
ing elements, leakage current could pass and adversely
DIIHFWWKHRSHUDWLRQRIWKHVROHQRLGYDOYH&RQ¿UPWKDW
WKHOHDNDJHFXUUHQWLVZLWKLQJWKHVSHFL¿FDWLRQRQ
theright.
Installation & Adjustment
Installation
Install in a manner tension will not be applied to the coil section lead wire.
Hold the product body when carrying the product. (Do not hold onto the lead wire)
Piping
Dirt or foreign matter in fluid may prevent the product from functioning correctly. Install a filter finer than 80 mesh.
When the regulator and solenoid valve are directly connected, the parts could mutually vibrate causing resonance and chattering.
If the piping cross section on the fluid supply side is restricted, operation may become unstable because of a differential pressure fault when the valve
functions. Use a pipe that matches the port size on the supply side.
During Use & Maintenance
During use
Instantaneous leakage phenomenon
When using the 2 port pilot operated solenoid valve, sudden application of pressure (e.g. starting up a pump) could momentarily open a closed valve and
FDXVHÀXLGWROHDN
Operation
Do not place a back pressure. There is a risk of malfunction.
Water-hammer
If you experience a water-hammer problem, please consider using CKD "WHL-type" or "RSV-type" solenoid valve or a motor valve.
Differential pressure
Keep the differential pressure 0.02 MPa or above between the primary and secondary sides with the valve open.
'LIIHUHQWLDOSUHVVXUHZLOOEHFRPHGLI¿FXOWWRJHQHUDWHEHWZHHQWKHSULPDU\DQGVHFRQGDU\LQWKHIROORZLQJFDVHV
,IDUHVWULFWLRQVXFKDVDQR]]OHLVDWWDFKHGWRWKHVHFRQGDU\VLGH
When valves are simultaneously opened in a state where multiple solenoid valves are piped in parallel.
Assembling & Disassembling
Tightening torque
7KHVFUHZPXVWEHWLJKWHQHGZLWKWKHWRUTXHVSHFL¿HGRQWKHULJKWIRU
disassembly and assembly.
CR circuit
Triode AC Switch
Leakage
current
C
R
Solenoid valve
Programmable controller side
Voltage
Model no.
AC
DC
100 V
200 V
24 V
FWD
3 mA or less 1.5 mA or less 1mA or less
Holder plate set screw
Body set screw
WR1ÂP
WR1ÂP