16
6.2.3
CG102IR Infrared Signal Control
Note: Infrared signal control is only available for the firmware version of 1.4.
To control CG102IR to send IR signal, following PDU is required send to CG102RS232
(IRCode please refer to the IRSI of the “IR Learning Tools”):
Cmd
DeviceID
1 byte
3 bytes
Device
Type
1 byte
Control
Cmd
1 byte
0x01
0x31
0x05
IRCode
1 byte
Figure 6-19 Request PDU of control CG102IR to send IR signal
If the CG102IR is able to send the IR signal, following PDU is expected to be returned from
CG102RS232:
Cmd
DeviceID
1 byte
3 bytes
0x02
Control
Result
1 byte
0x00
Device
Type
1 byte
Control
Cmd
1 byte
0x31
0x05
IRCode
1 byte
Figure 6-20 Response PDU of control CG102IR to send IR signal
If the target CG102IR cannot be reach during the control process, following PDU is expected
to be returned from CG102RS232:
Cmd
DeviceID
1 byte
3 bytes
0x02
Control
Result
1 byte
0x01
Device
Type
1 byte
Control
Cmd
1 byte
0x31
0x05
IRCode
1 byte
Figure 6-21 Response PDU of CG102IR not found