Figure 5, Right Side View
Right Side View, Mains Power
The PDS-375 TRX is provided with a universal input power supply and will operate on any
mains power source 100-240 VAC 50/60 Hz.
Each PDS-375 TRX is provided with a powerCON to NEMA 5-15P power cable. For use
outside of North America, the NEMA 5-15P can be removed and replaced with the correct local
connector. The power cord wire insulation color code is
Mains Hot
Brown
Mains Neutral
Blue
Safety Earth Ground
Green/Yellow
Color Kinetics CKDMX Output Pinout
The PDS-375 TRX CKDMX XLR 4P Output pinout is as follows:
PIN # Signal
CK Cable Wire Color
Pin 1
+24VDC
Red
Pin 2
(n/c)
Pin 3
Data
White
Pin 4
DC Common
Black
This pinout matches all Philips Color Kinetics ColorBlast 12 TRX, ColorBlast 12 TR, and iW
Blast 12 TR fixtures and all other CTI PDS units, and is the industry standard.
Page 9 of 31
6550 PDS-375 TRX Manual R6.docxx