background image

The PDS-375 TR Power Supply™ page 11 

 

 

                      

 

 

Specifications 
 
Dimensions: 

 12.785” W (with handle), 5.031” H, 6.828” D  

 
Weight:

  9.5 Lbs. 

 

Electrical Specifications: 

  Input Power 100-240VAC 50/60 Hz 600 Watts 

  Output Power 24VDC 14 Amps Max 

 
Features:   

  Heavy Duty NEMA 1 Steel and Aluminum enclosure 

  100-240 VAC 50/60hz Mains Power (auto-ranging) 

  Mounting points for C-Clamp & Safety Cable 

  (6) 4P XLRF  CK Data/24V Power output connectors for fixture connection 

  DMX 512 Interface (see below) 

  1 x 600 Watt internal power supply  

  24VDC 3A current limited per circuit output with LED Fault Indication 

  One-touch Mini-Zapi feature for reconfiguring fixtures with correct starting DMX 

Address  

  Includes 7 types of user-configurable fade and chase routines for stand-alone 

operation 

  In Stand-Alone Mode, selected routine is output to DMX Pass-Thru for synchronized 

Stand-Alone operation of many CB Supply systems 

 
DMX 512 Interface:

   

  DMX Input via 5P XLR Male 

  Isolated and repeated DMX Pass-Thru via 5P XLR Female 

  DMX Address interface utilizing 3 Rotary BCD Switches for DMX Address  

configuration 

 

CK Output Configuration 
 

  6 outputs providing Color Kinetics control protocol, +24VDC, and Ground 

  “CB Mode”: DMX converted to CK protocol and output selectively to each port as per 

BCD address setting (see below)  

   “iCove Mode”:  All 512 DMX values converted to CK Protocol and output on all ports 

 

Compliance 

  ETL Listed, Conforms to UL 508A 

  cETL Listed, Certified to Can/CSA Standard 22.2 14-95 

 

*Fixtures Supported:  

ColorBlast 12, ColorBlast 6, ColorBurst 6®, ColorBurst 4®, iColor Cove® 

 
 

Содержание PDS-375 TR

Страница 1: ...PDS 375 TR Touring Power Supply Operator s Manual Rev 1 0 2005 City Theatrical Inc Patent Pending ...

Страница 2: ...t Panel Controls 4 Back Panel Features 5 Mains Power Requirements 6 Connecting Color Kinetics fixtures to the PDS 375 TR 6 Operating Modes CB Pass Thru or Stand Alone 6 CB Mode 6 Pass Thru Mode 7 Stand Alone Effects Mode 7 Using the Mini Zapi 10 Installing the PDS 375 TR 10 Specifications 11 FIGURES Figure 1 PDS 375 TR Front Panel 4 Figure 2 PDS 375 TR Back Panel 5 Figure 3 PDS 375 TR with C Clamp...

Страница 3: ...ended for indoor use only Keep the unit dry Do not operate the unit if it gets wet Do not operate in excessive heat direct sunlight Be sure installation provides adequate ventilation Both the front and the back side of the unit must be clear of obstruction and allow free airflow There are no user serviceable parts inside Refer to qualified service personnel Compliance Certifications ETL Listed Con...

Страница 4: ...oad indicators and a Mini Zapi Switch All the control functions are described below 1 Pilot Status Light On Power Present System running Blinking No DMX Solid DMX Present Green CB Mode Orange Pass Thru Mode Alternating Red Green Stand Alone Mode 2 Reset Switch Press to reset the PDS 375 TR s system microprocessor 3 DMX Address Switches Left to right 100 s 10 s 1 s Set address to 000 for Pass Thru ...

Страница 5: ... BRONX NY 10454 VOICE 718 292 7932 FAX 718 292 7482 RED WHITE BLACK GND DATA n c 24VDC PIN 4 PIN 3 PIN 2 PIN 1 4P XLR PIN OUT 1 CB12 2 CB6s OR 8 iCOLOR COVES MAX PER OUTPUT 1 2 3 4 5 6 DMX OUT DMX IN FUSE 5 AMPS NEMA 1 ENCLOSURE MANUFACTURED BY CAN CSA STD C22 2 NO 14 95 CERTIFIED TO C MIXED VOLTAGE INTERFACE PANEL 9801635 ETL LISTED CONFORMS TO UL STD 508A 6 x 3 AMPS 24VDC MAX OUTPUT 100 240 VAC ...

Страница 6: ...r Stand Alone The Unit can be configured for either DMX managed CB Mode Pass Thru mode or Stand Alone Mode CB Mode In CB Mode the system will route DMX as CK Data protocol to each output based on the selected DMX starting address Each fixture is set as CK Light 1 DMX 001 002 003 The PDS 375 s internal DMX Manager selectively routes DMX Data to each light output so that each light receives only the...

Страница 7: ...mmed effects without need for a console This is very useful for events like parties or trade shows where a constantly running program is desired without the use of a console or show programming The unit is placed into Stand Alone Mode using the Config BCD switch When the unit is in Stand Alone mode the DMX Address switches become Effect controls Different Stand Alone Effects are selected via diffe...

Страница 8: ...in 34 8 min 35 9 min 36 10 min 37 12 min 38 15 min 39 20 min 40 25 min 41 30 min 42 40 min 43 50 min 44 1 hr 45 1 5 hr 46 2 hr 3 Color Wash reverse Same as above but in counter clockwise rotation White Yellow Green Cyan Blue Magenta Red 4 Cross Fade The Cross Fade effect changes from one preset color to another than back again The DMX 100s switch sets the starting color and the DMX 10s switch sets...

Страница 9: ...c 2 15 sec 3 2 sec 4 275 sec 5 325 sec 6 375 sec 7 5 sec 8 625 sec 9 95 sec 10 1 25 sec 11 1 5 sec 12 1 875 sec 13 2 5 sec 14 3 125 sec 15 4 375 sec 16 5 625 sec 17 6 25 sec 18 9 375 sec 19 12 5 sec 20 15 sec 21 18 75 sec 22 31 25 sec 23 37 5 sec 24 56 25 sec 25 1 25 min 26 1 875 min 27 2 5 min 28 3 125 min 29 3 75 min 6 Fixed color strobe uses the DMX 100s switch to choose the color 1 Red 2 Green...

Страница 10: ...ight red for a moment and then flicker for a few seconds 6 After the flickering stops Power the system down 7 Power the system back up to test the units Installing the PDS 375 TR The PDS 375 TR can be mounted to a pipe or truss using a standard theatrical C clamp The unit is provided with a hole in the center of the handle for attaching the C clamp and with holes in the handle base for a safety ca...

Страница 11: ...es 7 types of user configurable fade and chase routines for stand alone operation In Stand Alone Mode selected routine is output to DMX Pass Thru for synchronized Stand Alone operation of many CB Supply systems DMX 512 Interface DMX Input via 5P XLR Male Isolated and repeated DMX Pass Thru via 5P XLR Female DMX Address interface utilizing 3 Rotary BCD Switches for DMX Address configuration CK Outp...

Отзывы: