background image

 SR17C-E-0716.doc         SIZE: 140x75mm         SCALE 2:1         2003/10/4 

-E7- 

[ DATA ], [ DEL ] Data Entry and Delete Key 

In the STAT mode, enter data by pressing the desired numbers, then 
[ DATA ]. If you enter incorrect data and do not notice your mistake 
until you press [ DATA ], enter the same incorrect data and then press 
[ DEL ] to delete that incorrect data.  

[

x

 ] Arithmetic Mean Key 

Calculates the arithmetic mean (

x

 ) of the data. 

[ 2ndF ] [

Ӻ

] Population Standard Deviation Key 

Calculates the population standard deviation of the data. 

[ s ] Sample Standard Deviation Key 

Calculates the sample standard deviation of the data. 

[ 2ndF ] [

Ӣ

x

2

] Sum of Square Value Key 

Calculates the sum of the square value (

Ӣ

x

2

) of the data. 

[ 2ndF ] [ 

Ӣ

x ] Sum of Value Key 

Calculates the sum of the value (

Ӣ

x ) of the data. 

[ n ] Number of Data Key 

Displays the number of data (n) entries. 

The Display 

Indicators showed on the display to indicate you the current status of 
the calculator. 

• 

Floating point displays up to 10 digits. 

• 

The mantissa section displays up to 8 digits. the exponent section 
displays up to 

²

99.

STAT 

:  Indicates the statistical mode. 

:  Indicates that a value is stored in 

memory. 

– 

:  Appears to the left of the mantissa or 

exponent to indicate that the respec-
tive value is negative. 

:  Indicates an error. 

PGM 

:  Indicates the program learn mode. 

CONST 

:  Indicates the constant mode. 

GRAD 

:  Indicates the gradient units have been 

selected.

RAD 

:  Indicates that radian units have been 

selected.

DEG 

:  indicates that degree units have been 

selected.

BUSY 

:  While an operation is executing.

Ӻ

 : 

Indicates the deviation value 

Содержание SRP-265

Страница 1: ...RROR CONDITIONS 9 POWER SUPPLY 10 NORMAL CALCULATIONS 10 Basic Calculation Including Parenthesis Calculations 10 Constant Calculations 10 Memory Calculations 11 FUNCTION CALCULATIONS 11 Sexagesimal De...

Страница 2: ...nce to enter numbers x Basic Calculation Keys Press these keys in their logical sequence for addition subtraction multiplication division and to display answers ON C Power On Clear Key Press ON C to t...

Страница 3: ...ingle calculation EXP Exponent Key To enter a number in scientific notation first enter the numbers for the mantissa press EXP and then enter the numbers for the exponent 2ndF Key Press 2ndF to displa...

Страница 4: ...ters Pressing 2ndF A B before ln cm can convert a number in centimeters to inches Key Meanings in cm inch centimeter feet m feet meter feet 2 m 2 feet 2 meter 2 B gal l Britain gallon liter gal l gall...

Страница 5: ...hm of the displayed value press ln To calculate the natural antilogarithm of the displayed value press 2ndF e x x 2 Square Root And Square Keys Press to find the square root of the displayed value To...

Страница 6: ...1 0 Dielectric permittivity 8 854187817 x 10 12 Fm 1 PROGRAMMING KEYS USE IN THE PGM MODE ONLY 2ndF PGM Program Mode Set and Clear Key Set the calculator to the learn program mode PGM appears on the...

Страница 7: ...data 2ndF x Sum of Value Key Calculates the sum of the value x of the data n Number of Data Key Displays the number of data n entries The Display Indicators showed on the display to indicate you the c...

Страница 8: ...sin tan cos 1 sin 1 tan 1 log ln x 2 1 x 3 X and 13 units conversion 2 Operation in parenthesis 3 Functions required pressing the function key before entering for example EXP key 4 Fractions 5 6 y x...

Страница 9: ...nator are less than 1 x 10 10 STAT x 1 x 10 50 x 1 x 10 100 0 x 2 1 x 10100 0 n 1 x 10 100 x n 0 s n 1 n 0 OVERFLOW ERROR CONDITIONS A symbol E is indicated on the display when any of the following co...

Страница 10: ...The calculator uses two alkaline button batteries GP76A LR44 for power If the display becomes dim and difficult to read the batteries should be replaced as soon as possible To replace batteries Remove...

Страница 11: ...ntents press 0 X M or ON C X M in sequence M appears when a number which is not equal to 0 is stored in memory When you press X M after pressing MR the displayed num ber is changed as the contents of...

Страница 12: ...s a decimal Ex 9 19 16 7 9 4 3 3 9 4 5 5 c b a 4 c b a 9 3 c b a 3 c b a 4 DEG 9 7 36 c b a DEG 9 19 Trigonometric Inverse Tri Functions Ex 3 sin 30 1 50 3 x 30 sin DEG 1 50 Ex cos 3 2 rad 0 5 2 x 2nd...

Страница 13: ...2 2 3 x 5 DEG 5 29 Ex 1 29 27 5 3 3 5 2ndF 3 27 2ndF 3 DEG 1 29 Ex 7 5 16807 7 x y 5 DEG 16807 00 Ex 2 32 5 32 2ndF y x 5 DEG 2 00 Ex 12 00 4 1 3 1 1 3 2ndF 1 x 4 2ndF 1 x 2ndF 1 x DEG 12 00 Ex 123 3...

Страница 14: ...tistical calculation mode Press 2ndF CAD to clear statistical memory before you start a new calculation Instead of entering directly each data when often several item of data have the same value you c...

Страница 15: ...ow enter your procedure as if you were just going to calcualte it once except press 2ndF x before entering variable data You get your first answer while you are still in the PGM mode Note If you press...

Страница 16: ...ame method to program your calculator to run two or more formulas One after another Ex Find the total amount of principal and interest on a 5 000 loan x at 6 annual interest y compounded annually over...

Страница 17: ...3 82 R 3 30 12 2ndF Ka x k DEG 12 47 2ndF Kb x k DEG 47 82 X M M DEG 82 2ndF PGM M PGM DEG 0 Ka x k Kb x k M PGM DEG 564 R1 x R2 Ka x k Kb x k MR M PGM DEG 4 R4 2ndF HALT M PGM DEG 4 MR Kb x k M PGM...

Страница 18: ...SR17C E 0716 doc SIZE 140x75mm SCALE 2 1 2003 10 4 E18 RUN M DEG 10 R5 RUN M DEG 5 R6...

Отзывы: