13
Check Items
How to Check
Results and Treatments
* Refer to Basic Course:
II
-2-e.
• Since this watch is energized by light, it should receive
light as much as possible. If the watch is placed near a
light source which generates heat (above 60°C / 140°F)
such as an incandescent lamp, a halogen lamp, etc., its
functions and parts may be deteriorated or deformed by
the heat. Accordingly, take care when applying light to it.
• It is important to check that the secondary battery is
charged normally (the customer knows that this watch is
a solar watch) and expain the correct charging method
to the customer.
Confirmation of
using condition
•
Current consumption of the
movement
Under 0.5µA
→
Normal
Over 0.5µA
→
Check train wheel and
dial-side mechanism.
→
Remove dust and dirt.
h
•
Current consumption mea-
sured again
Over 0.5µA
→
Replace the unit of
electronic circuit.
Measurement of
current
consumption
* Refer to Technical Manual, Basic Course:
II
-1-f.
• This watch uses the secondary battery block, instead of
a ordinary battery. Accordingly, prepare a silver battery
(1.55V) and measure the current consumption according
to the following procedure.
(1) Remove the secondary battery.
(2) Referring to Technical Manual, Basic Course, set the
silver battery (1.55V) to the adapter of the tester cor-
rectly.
(3) Pull the crown out.
(4) Set the tester.
Note:
When measuring the current consumption, do not
apply any light to the solar cell. If any light is applied,
the voltage changes and correct current consump-
tion cannot be measured.
<Tester range: DC 10µA>
(5) Return the crown to the normal position and measure
the current consumption of the movement.
J A P A N
NO JEWELS
WAT C H C O .
A1
(- )
CITIZEN
E 1 0 1 M
9
10
11
Check of appear-
ance and
function
* Refer to Basic Course:
II