Citizen Eco-Drive H360M Скачать руководство пользователя страница 2

5

English

  Checking the Reference Position

Before using the watch, check that the hands are aligned with “0”, similar to when setting 
weighing scales

  The reference position may become misaligned when the watch is exposed to 

strong magnetism, static electricity or impacts.

Even if radio waves are received, the correct time will not be indicated unless the 
watch hands are aligned to the correct reference position. Check that the hands 
are properly aligned with “0”.

[Examples of magnetic products that can affect the watch.]

•  Health products (for example, medical necklaces and waist bands that have magnetic fi elds)
• Refrigerators (magnetic part of the door)
• Electromagnetic cookers
• Bags (with magnet fasteners)
• Mobile phones (speaker part)

2

 

Check that the reference position aligns correctly in 
the 12:00:00 position.

(1) With the crown in the normal position, press the 

upper right button 

B

 continuously for about 5 

seconds.

(2) Release the upper right button 

when the 

second hand begins to move.
The hands will move rapidly, stopping at the 
reference position recorded in the watch 
memory.

 

The hands are aligned with the 12:00:00 position.

Correct reference position

12:00:00

Check the 

reference 

position

Button 

B

Crown

Reference position is 
correct

Reference position is 
incorrect

  The hands are not aligned with the 12:00:00 position.
  Pull out the crown and correct the reference position. (p. 11)

Press the upper right button 

B

, or leave the watch 

for 2 minutes, and the hands will return to their 
normal movement.

Содержание Eco-Drive H360M

Страница 1: ...he watch as indicated in Guide to Charging Time p 14 Charge the watch in direct sunlight for a long time once a month Please confirm the following before using the watch 1 The second hand is moving at...

Страница 2: ...Electromagnetic cookers Bags with magnet fasteners Mobile phones speaker part 2 Check that the reference position aligns correctly in the 12 00 00 position 1 With the crown in the normal position pres...

Страница 3: ...ence One step of the second hand indicates a one hour time difference Setting the summer time p 9 Press the lower right button A once then within 10 seconds press the upper right button B The second h...

Страница 4: ...receiving a radio signal Average monthly deviation 15 seconds when used in of room temperature 5 C to 35 C 40 F to 140 F Operating temperature 10 C to 60 C 14 F to 140 F Converter Bipolar step motor T...

Страница 5: ...nt of the hands turn the crown to the left or right by one click A gentle click can be felt by the fingertips Using the side of your finger quickly turn the crown by two or more clicks Hour hand Summe...

Страница 6: ...due to the surroundings or metal shielding When inside a building place the watch as close to a window as possible for good reception Radio signal reception may be difficult during the hours around su...

Страница 7: ...al can be easily received pointing the 9 00 position in the direction of the radio signal transmitter 2 Press the lower right button A for more than 2 seconds and release it when the second hand stops...

Страница 8: ...inflingen Transmitter Southeast Frankfurt The standard time radio wave this watch uses is broadcast almost continuously 24 hours a day but may occasionally be interrupted for maintenance Even if recep...

Страница 9: ...e to receive the standard time signal or if in a region where the summer time is used and standard time signal cannot be received Setting summer time Note Do not hold the lower right button A If you d...

Страница 10: ...ent time zone the time difference can be set in 1 hour units 27 hours to match the local time using the second hand 1 Press the upper right button B once The second hand will stop at the 12 00 positio...

Страница 11: ...pidly return to the current time If the watch is left for 2 minutes the hands will return to their normal movement In the event that the time is not correct carry out On Demand Reception p 7 7 SOLAR P...

Страница 12: ...When the watch is recharged sufficiently it will receive the radio signal automatically once 1 When the watch stopped due to insufficient charging It takes at least 30 minutes to recharge sufficientl...

Страница 13: ...to show that the watch is insufficiently charged The watch will stop due to an insufficient charging about 2 days after starting the 2 second interval movement Note During 2 second interval movement...

Страница 14: ...it will take a long time to recharge it as is indicated in the table when it stops due to an insufficient charging Furthermore it is recommended to charge your watch by exposing to direct sunlight fo...

Страница 15: ...al with the 9 00 position of the watch pointing towards a window Find a location such as window that is conducive to radio signal reception and change the watch location direction and angle p 6 Was th...

Отзывы: