36
37
13. All-Reset
• This watch may not function properly as a result of being subjected to the
effects of static electricity, strong impact and so forth. When this happens,
perform the All-Reset and Base Position Alignment procedures described
below. If the base position alignment procedure is not performed after
performing the all-reset procedure, the base positions of each hand will be
incorrect, and the time will not be displayed correctly even if it has been set.
In addition, failure to perform the base position alignment procedure will also
prevent the alarm and chronograph modes from operating properly.
• When performing the all-reset procedure, first make sure that the watch is
sufficiently charged and the second hand is moving in one second increments.
If the all-reset procedure is performed when the watch is insufficiently
charged, it may not function properly or remain stopped following the all-
reset procedure.
AL
-2
A
L
-1
A
L
-1
C
H
R
TME
TME CH
R
A
L-
2
24
18
12
6
.0
.8
.2
.4
.6
1
(0) Normal position
(2) 0-position correction
Button (A)
Button (B)
[All-Reset Procedure]
1. Turn the crown to set the mode hand to the chronograph [CHR] mode.
2. Pull the crown out to Position 2 (0-position correction mode).
• With the exception of the mode hand, each hand moves to its respective 0-
position stored in memory and stops. (A hand may stop at a position other
than the 12:00 position if its 0-position has shifted.)
3. Press buttons (A) and (B) simultaneously and then release.