CL-S300 Series Service Manual
- 11 -
(5)“SA LABEL SENSOR SP 300(PPS00172-00)”
Unscrew to open the bottom cover.
Lift up the AC adapter.
Unplug the connector for the label sensor from
the main PCB.
The label sensor is held with a plastic ring by two hooks.
Press two hooks to take out the plastic ring.
Pull out the sensor.