5. Memory recall

You can recall stored data by pressing the
“Memory” switch, except when performing a
measurement.
• Up to 99 sets of measurement results are auto-

matically stored in memory, and memory cell
No. 1 is always used to store the oldest set of
results.

• Press “Memory” switch, the memory cell num-

ber with the stored measurement results (Sys-
tolic / Diastolic and Pulse with Date/Time) are
displayed for 1 minute.

* Pressing “Memory” button, nothing will appear

on the display if there is no data in the memory.

• If the “Memory” switch is pressed further, the

old date are indicated in the order of the time
series.

• Press “Start/Stop” switch to turn off the unit.

6. Memory clear function

To clear memory data, take out the two batteries
at same time and then press the “START/STOP”
switch for a while.  All memory is erased.

Press the “POWER/START” switch to turn off.

CAUTION

To discontinue a measurement for any reason,
press the “POWER/START” switch. This causes
the “wrist cuff” to deflate rapidly.

Содержание CH607

Страница 1: ...s Deutch Italiano Fran ais INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH607 Eng 1 TIME S E T M O D E M E M O R Y DATE M SYS mmHg mmHg P DIA mmHg PULSE MIN START STOP CH607 English Es...

Страница 2: ...t be too impressed by the results of one measurement Keep a record of blood pressure variations Many readings tell a story Emotional stress may tend to cause blood pres sure to rise This product shoul...

Страница 3: ...gularity reduce the pressure by immediately switching off the power or removing the batteries and consult the sale outlet where you purchased If you think the measured value is abnormal or if measurin...

Страница 4: ...Sterilizing alcohol or a neutral detergent and then wipe it with a dry cloth Do NOT use thinner or benzene Nature and frequency of mainte nance This product is designed for use over an extended perio...

Страница 5: ...with the following standards EN 1060 1995 Noninvasive Sphygmomanometers Part 1 General Require ments and EN 1060 1997 Noninvasive Sphygmo manometers Part 3 Supplementary Requirements for Electromecha...

Страница 6: ...DATE M SYS mmHg mmHg P DIA mmHg PULSE MIN START STOP CH607 Eng 6 LCD display Wrist cuff Recall memory button Start Stop button Batteries AAA 1 5V 2 DEVICE DESCRIPTION Carrying case Setting button Mode...

Страница 7: ...iano Fran ais Eng 7 2 Description of display symbols Month Date Hour Minute Afternoon time Systolic rate Pulse rate Pulse symbol Battery weak display Error symbol Memory record Diastolic rate Blood pr...

Страница 8: ...atteries or equivalent are suitable for this blood pressure monitor All batteries used must be same type Do not mix alkaline stan dard carbon Zinc or rechargeable cadmium batteries Also do not mix old...

Страница 9: ...e cor rect date Each time the Set switch is pressed the value of the date is increased by one The value of hour can be corrected in only the forward direction 3 Press the Mode switch then Hour starts...

Страница 10: ...are seated and with your left hand on a table held a level with your heart Keep your body still and relaxed during measurement Measurement Procedures for People With a Weak Pulse Apply the middle part...

Страница 11: ...ry When there are already 99 sets of results in memory the oldest one is automatically erased and overwritten with the newest Display of the measurement result will continue until power is turned off...

Страница 12: ...are displayed for 1 minute Pressing Memory button nothing will appear on the display if there is no data in the memory If the Memory switch is pressed further the old date are indicated in the order...

Страница 13: ...ac curately Press Start Stop switch again and re measure Or check cuff if wrapped at the wrist or according to instructions Check palm if exerting effort Check if talking or moving during measurement...

Страница 14: ...Automatic Inflation by Air Pump Deflation Automatic Air release control valve Exhaust Quick Exhaust Valve Rated Voltage 3 V DC Power Source 2 AAA Size Batteries Power Consumption 0 1 W Battery Life A...

Отзывы: