Eng 8

 -

The heart symbol flashes, and the buzzer sounds
for 1 second. Once the measurement prepara-
tions are completed, the buzzer sounds three
more times.
If batteries become weak, “

” mark is dis-

played and measurement is discontinued.

Pressurization and measuring start.

When a pulse is detected, the pressure  value
moves to the lower side of the display. At this
time the mark  “

Q

” flashes and buzzer beeps.

Once the blood-pressure measurement has sta-
bilized, pressurization is discontinued, the air in
the cuff is automatically let out, the buzzer
sounds for about 2 seconds, and the high and
low blood pressure are respectively displayed
one above the other.

Unless an error is generated, the measurement
results are automatically stored in memory. Up
to 7 sets of results can be stored in memory.

Содержание CH-656C

Страница 1: ...English Espa ol Portugu s Deutch Italiano Fran ais INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH 656C Eng 1 M...

Страница 2: ...tc prior to measurement may affect the results The blood pressure varies constantly throughout the day Measurement should be made regularly at the same time each day Do NOT be impressed by the results...

Страница 3: ...ressure when it is too cold below 10 C or too hot above 40 C in the room Do NOT measure blood pressure immediately after drinking coffee or tea or smoking Measure blood pressure with a relaxed and qui...

Страница 4: ...teries when not in use for a long period Do NOT disassemble the apparatus Do NOT bend the cuff or air hose unnecessar ily NEVER wipe the blood pressure monitor with thinner or benzene as they may dama...

Страница 5: ...ortugu s Deutch Italiano Fran ais Eng 5 Systolic blood pressure display section Diastolic blood pressure Pulse display section Wrist cuff Memory recall switch Power Start switch Battry cover IDENTIFIC...

Страница 6: ...and polarities on each battery with the polarity marks on the case 3 LR03 batteries or equivalent is suitable for this blood pressure meter 1 Attaching of wrist cuff The blood pressure is measured at...

Страница 7: ...unit too tightly Keep your left wrist relaxed during measure ment period Do not apply physical pressure against unit with wrist before or during measurement All measurements must be performed while y...

Страница 8: ...e pressure value moves to the lower side of the display At this time the mark Q flashes and buzzer beeps Once the blood pressure measurement has sta bilized pressurization is discontinued the air in t...

Страница 9: ...of the mea surement result will continue until power is turned off 3 Turn Power off Press the POWER START switch to turn off CAUTION To discontinue a measurement for any reason press the POWER START s...

Страница 10: ...lts can be stored in memory and memory cell No 1 is always used to store the newest set of re sults M When pressing the Memory recall switch the memory cell number is displayed then the stored measure...

Страница 11: ...Deutch Italiano Fran ais Eng 11 6 Memory clear function While the memory datum to be cleared are in dicated and when the Memory recall switch is continued to push for 3 seconds buzzer beeps and the m...

Страница 12: ...e has a trouble Appears when the pulse could not be measured Appears when the batteries become weak Device has a trouble DESCRIPTION OF DISPLAY MARKS Exhaust the air with in the cuff After winding the...

Страница 13: ...EN is a registered trademark of Citizen Watch Co Japan Consumer Electronics Division CBM Bldg 5F 5 68 10 Nakano Nakano ku Tokyo 164 0001 Japan Phone 03 5345 7430 Fax 03 5345 7431 E mail info con jcbm...