1. Installing battery

Insert the cuff hose and bulb hose into the hose connector.

2. Inserting hoses

Take off the battery cover at the back of the unit by sliding it
as shown.

Install a 9V battery (6F22, 6LR61) taking care for the polarity.

Protect the nature environment:

Please help protect natural environment by respecting national
and/or local recycling regulations when disposing of the bat-
teries and the products at the end of their useful lives.

Reference European standard:

This products complies with EC instructions 93/42/EEC (Medi-
cal Device Directive) and with the following standards: EN 1060-
1 : 1995 “Noninvasive Sphygmomanometers, Part 1 General
Requirements” and EN 1060-3 : 1997 “Noninvasive Sphygmo-
manometers, Part 3 Supplementary Requirements” for Elec-
tromechanical Blood-Pressure Measuring Systems.

Manufacturer:

Name:

Premier Precision Ltd.

Address:

Block E, G-H, 6

th

 floor,

Phase 2, Yip Fat Factory Building,
73-75 Hoi Yuen Road,
Kwun Tong, Kowloon, Hong Kong

European Representative:

Name:

WvW elektronische Geräte Vertrieb GmbH.

Address:

Robert-Koch-Straße 20,
D-80538 München,
GERMANY

PREPARATION FOR MEASUREMENTS

Bulb hose

Cuff hose

English

Eng 5

 -

Содержание CH-302B

Страница 1: ...TOR REF CH 302B TM IDENTIFICATION OF PARTS Systolic blood pressure display section Diastolic blood pressure Pulse display section Exhaust button Bulb Air release system Bulb hose Cuff Power switch Cuf...

Страница 2: ...the event of improvements being made SPECIFICATIONS Oscillometric system Digital display Height 10mm Pressure 0 280mmHg Pulse 40 200 beat min Pressure 3mmHg Pulse 5 Manual inflation by bulb Automatic...

Страница 3: ...mpressed by the results of one measurement Keep a record of blood pressure variations Many readings tell a story Emotional stress may tend to cause pressure to rise For proper measurement of blood pre...

Страница 4: ...the center of the cuff at the level of your heart and do NOT move your arm or talk during measurement Do NOT keep on measuring so many times as your arm will have built up congestion of blood and you...

Страница 5: ...ndard This products complies with EC instructions 93 42 EEC Medi cal Device Directive and with the following standards EN 1060 1 1995 Noninvasive Sphygmomanometers Part 1 General Requirements and EN 1...

Страница 6: ...s or jacket up over the arm this will constrict the upper arm and prevent accurate measurement The cuff hose should be placed on the inside of your arm as figures The cuff should be wound so that one...

Страница 7: ...s some air re maining in the cuff release air with the exhaust button until the 0 appears The buzzer beeps 3 times Unit is now ready to take new measurement Value of the pulse is not memorized nor dis...

Страница 8: ...appear on Flashing Flashing Flashing Altemate display 5 Power off Touch the power switch for power off If this unit is left on after measurement an auto matic power off function turns the power off a...

Страница 9: ...RIPTION OF DISPLAY MARKS The cuff was not inflated to more than 30 40 mmHg above your systolic pressure Raise the set pressure value by higher level The cuff was inflated to more than 320 mmHg Exhaust...

Страница 10: ...EN is a registered trademark of Citizen Watch Co Japan Consumer Electronics Division CBM Bldg 5F 5 68 10 Nakano Nakano ku Tokyo 164 0001 Japan Phone 03 5345 7430 Fax 03 5345 7431 E mail info con jcbm...

Отзывы: