Citizen CAL.0S Series Скачать руководство пользователя страница 4

"A"

RESET 

"A"

     TIME MEASUREMENT

 

STOP

"B"

"A"

"B"

E) CHRONOGRAPH RESET  (INCL. AFTER REPLACING BATTERY)
This procedure shoud be performed when the chronograph second hand and 
chronograph 1/20(1/1) second hand do not return to the 0 second position after the 
chronograph has been reset, and including after the battery has been replaced.

1. Pull the crown out to the 2nd position.
2. Press button "A" to set the chronograph second hand to the 0 position. 
3. Press button "B" to set the chronograph 1/20 second hand to 0 position.
The chronograph hands can be advanced rapidly by continuously pressing button 
"A"or "B". 
4. Once the hands have been zeroed, reset the time and return the crown to its 
normal position.
5. Press button "B" to check that the chronograph hands are reset to the 0 position.

* Do not return crown to normal position while chronograph second hand and 1/20 
chronograph second hand return to 12:00 (ZERO) position. 
Each hands stop on the way when crown are returned to normal position and these 
positions are recognized as 12:00 (ZERO) position.

F) FITTING METHOD OF HANDS
Place the module on case back shown in the figure and position the reference hand,   
then fit the hands according to the following procedure.

1. Pull out the crown to the time setting position.
2. Turn the crown to the left, and stop it just after the date changes. After the date  
starts changing, Turn the crown slowly.
3. Push in the crown by one step, taking care not to turn it.
4.Fit the reference hand,hour hand and minute hand to the 12-o'clock position.
 When fitting the hands, remove  the case back and place the movement on work stand.

Chronograph
minute hand

Hour hand

Chronograph
hour hand

Second hand
or 1/20 sec
chronograph hand

Minute hand

Normal crown
position

Button B

Button A

Calendar

Chronograph
second hand

Отзывы: