background image

o

 

Internally, the atomizer breaks up a high grade medicinal mineral proprietary formula into 

such tiny particles, that it produces an opaque haze that is filtered several times to remove 
larger size particles (over 20 microns) before it is mixed with the ambient air thrown 25’ from 
the machine.   

o

 

Because lights and lasers look best when fog is evenly distributed throughout the room, the 

hazer has two built in circulation fans that circulate the air from the room with the haze.  This 
atmospheric effect lasts over 2-3 hours and is evenly dispersed from floor to ceiling, wall to 
wall. 

o

 

In just 3 months, a StarHazer II

TM

 Haze Machine owner, using High Performance Fluid 

(formerly called Diffusion Fluid) can regain the cost of this machine through lower costs of 
operation…1/16 electricity, 1/30 fluid, and no breakdowns compared to hazers half the price 
when used daily, year after year. 

o

 

When the StarHazer II™ Haze Machine timer on the remote control (included) is used, you 

have 100% less chance of ever having residue from over-hazing (turn it on and leave). Now 
you can just set the timer and the unit will automatically, constantly turn on/off your unit 
when the timer comes on.  

 
 
 

1.

 

Safety instructions 

 

WARNING: Read and understand all labels and operating 

instructions before attempting installation. 

 

o

 

Risk of electrical shock- 

Never open the machine without disconnecting power lead first! 

This device is supplied with a grounding conductor. To reduce risk of electrical shock, 
connect only to properly grounded, grounding type receptacles. Never remove the third prong 
from the plug. 

o

 

This machine requires a 120VAC/10 A circuit for operation.  During  operation a circuit 
should be dedicated to the StarHazer II

TM

 Haze Machine.  If you have any doubts about the 

capacity or grounding of your existing circuits, consult a qualified electrician.  

o

 

Never use water-based fluids.

 This would cause irreversible damage to the tank. Operating 

the pump with other than CITC Oil-based hazing fluid is not covered under warranty. 

o

 

Be sure area around hazer is dry before applying electrical power. 

o

 

Make sure that your unit is pointed in a direction that leaves a 12ft (4m) open area out in 
front. Place the front of the machine away from direct contact with electrical instruments and 
people.  There is no heat in this unit.    

o

 

Fluid is very slippery when spilled.  Care in keeping any drips or spills cleaned up is 
necessary. 

o

 

Do not store StarHazer II 

TM

 Haze Machine in freezing conditions. Below 50

F it will not 

start.

 

 
                             

  

5. Operating the 

STARHAZER II

TM

 Haze Machine

 

 

5.1

 

 Selecting the Location 

 

Secure a good location for the machine to rest solidly on the floor so that the output of the 
machine will not be restricted. Make sure that your unit is pointed in a direction that leaves an 

Содержание STARHazer II

Страница 1: ...STARHazer IITM Operating Instructions P N 100033 100038 120 VAC 230v...

Страница 2: ...uct is quite extensive To guarantee perfect and successful work with this machine please take some time to read the manual carefully And finally we believe you will enjoy years of great haze effects i...

Страница 3: ...ng the StarHazerTM 5 5 1 Selecting the Location 5 2 Electrical Power Requirements 5 3 Hooking things up 5 4 Operating the machine 5 5 Troubleshooting 5 6 Notes on Optional DMX Control 6 Service and Ma...

Страница 4: ...to breathe There is no odor with toxin free High Performance Fluid haze One tiny half ounce of fluid per hour of constant operation testifies to the tiny amount of particles being used to create such...

Страница 5: ...g installation o Risk of electrical shock Never open the machine without disconnecting power lead first This device is supplied with a grounding conductor To reduce risk of electrical shock connect on...

Страница 6: ...causing irreversible damage to the tank and possibly damaging the compressor or hoses 2 Check for proper matching voltage outlet Plug in cord provided 5 4 Operating the machine 1 Allow a 12 open area...

Страница 7: ...fluid for clarity If separation is seen discard and fill with fresh fluid 5 5 Troubleshooting 1 If the fuse blows If hazer stops working first check fuse located under the plug Remove the plug With a...

Страница 8: ...e and Maintenance Care of your StarHazer IITM will give you years of service Note cleaning your unit is going to pay off in constant good performance 1 When finished wipe machine with a clean cloth an...

Страница 9: ...Limited Warranty Five year limited warranty on tank and compressor 90 days on electrical components Remote Control On off cycle timer 25 cord 3 pin XLR in out connectors 0 60 s On 0 4 m Off Added Fea...

Страница 10: ...not guarantee replacement rights nor do faults or defects caused by water by generally abnormal environment conditions or Force Majeure 1 Faulty parts will be repaired or replaced manufacturer s choi...

Страница 11: ...vice do not forget to remove any liquid from the fluid bottle and place unit in original box Obtain your RMA by calling CITC Payment arrangements for repair must be made before receiving RMA in case u...

Отзывы: