Dryer Installation with Multiple Exhaust
DRYER INSTALLATION
WITH MULTIPLE EXHAUST
For Exhaust Duct more than 14 feet (5 m) and 2 elbows equivalent and
more than 0.3 inches (8 mm) static pressure.
(See illustration on next page.)
1.
Make-up air from outside building may enter enclosure from top or
side walls. (See Dryer Make-Up Air Requirements Chart)
2.
Use constant diameter duct with area equal to the sum of dryer duct
areas.
EXAMPLE: 6-8 inch (203 mm) diameter duct = 1-19.6 inches (498
mm) diameter duct in area. Use 20 inches (508 mm) diameter duct or
diameter to match tube-axial fan.
3.
Enclosure (plenum) with service door. This separates the dryer air from
room comfort air. If dryers use room air instead of outside air, the heat
loss can be another 25 Btu/h (6.3 kcal/h) for each cubic foot per minute
(cfm) used.
4.
Zero inches clearance to combustible material allowed on sides and at
points within 4 inches (100 mm) of front on top.
5.
Heat loss into laundry room from dryer fronts only is about 60 Btu/h
per square foot (15 kcal/h per 0.1m²).
6.
Flange mounted, belt driven tube-axial fan. Fan must run when one or
more dryers are running. See suggested Automatic Electrical Control
Wiring Diagram on previous page. Must meet local electrical codes.
Fan air flow (cfm) (m³/min.) is equal to sum of dryer air flows, but
static pressure (SP) is dependent on length of pipe and number of
elbows.
7.
Barometric bypass damper—Adjust to closed flutter position with all
dryers and exhaust fan running. Must be located within enclosure
CAUTION: Never install hot water heaters or other gas appliances
in the same room as dryers. Never install cooling exhaust fans in the
same room as dryers.
CAUTION: Never exhaust dryers with other types of equipment.
Содержание L36URD30E
Страница 11: ...Page 11 50 lb Dryer Dimensions Standard Gas Steam and Electric Heated Illustration ...
Страница 12: ...Page 12 50 lb Dryer Dimensions Gas Energy Saver Model Illustration ...
Страница 24: ...Page 24 Steam Piping Installation Illustration ...
Страница 36: ...Page 36 Double Timer Models Illustration Double Timer Panel ...
Страница 43: ...Page 43 DIRECTSPARK IGNITIONOPERATION FLOW CHART ...
Страница 58: ...Page 58 50 lb Laundry Dryer Front Exploded View Illustration ...
Страница 60: ...Page 60 50 lb Laundry Dryer Single Motor Model Rear View Illustration ...
Страница 62: ...Page 62 50 lb Laundry Dryer Double Motor Model Rear View Illustration ...
Страница 76: ...Page 76 ...