Page 26
NOTE:
All HD dryers manufactured by are equipped with the
DSI (Direct Spark Ignition) modules. These are designed to in-
crease dryer efficiency and to reduce dryer operating costs. The
main burner is directly ignited from a spark electrode. A burning
flame provides an electrical path for a small amount of sensing
current to allow gas valve operation. If the main burner flame
extinguishes for amy reason (aside from the thermostatic control)
sensing current will shut down the gas valve and the spark ignition
circuit.
1. Once flame is established, the spark shuts off, and the main
burner flame is then electronically monitored by means of a
sensing spark probe which is located over the burner. The gas
valve remains energized (open).
2. If no flame is detected within the first 11 seconds the DSI will
go into a safety lock-out. The gas valve is energized.
3. If recovery from a safety lockout requires one of the following:
A. Opening the main door thus interrupting power to the DSI
module and allowing dryer diagnostic trouble shooting.
B. Disconnecting the entire dryer from a power source using a
circuit breaker of a switch.
4. By closing the main door the ignition circuit will be restored for
another trial of the ignition circuit.
5. Once the thermostatic control has been satisfied by reaching a
pre-set temperature or the drying timer has been timed out, the
ignition circuit will be de-energized thus extinguishing the
flames.
6. The dryer will continue to run in a cool-down mode without
heat. This process will cool the load to the touch and help to
eliminate wrinkling.
7. The cool - down time is pre-set on some models and manually set
on other dryer models. The cool-down cycle prevents fabric
wrinkles by allowing clothes to reach room ambient temperature
while still in a continuous levitation state until clothes are ready
to be folded or pressed.
Direct-Spark Ignition Operation
DIRECT SPARK
IGNITION
OPERATION
Содержание HD75.1