Page 14
Gas Piping Installation
1. The installation must conform with local codes, or in
the absence of local codes with the
National Fuel
Gas Code, ANSI Z223.1 or the CAN/CGA-B149,
Installation Codes.
2. Check Identification Nameplate for type of gas for
dryer.
3. Check for altitude elevation of dryer.
4. Check with utilities company for proper gas
pressure and gas supply line.
5. Natural Gas OnlyCheck the gas pressure inlet
supply to dryer, 11 inches water column (27.4 mbar)
maximum. Manifold Pressure3.5 inches water
column (8.8 mbar) pressure.
6. L.P. Gas OnlyCheck the gas pressure inlet supply
to dryer, 13 inches water column (32.4 mbar)
maximum. Manifold Pressure11 inches water
column (27.4 mbar) pressure.
GAS PIPING
INSTALLATION
CAUTION: Low gas pressure and intermittent gas will
cause gas ignition problems and inadequate drying of
laundry.