39
Catalyst 6500 Series Power over Ethernet Daughter Cards Field-Upgrade Installation Note
78-10826-08
Installing the Ethernet Switching Module
Installing the Ethernet Switching Module
Caution
To prevent ESD damage, handle the modules by the carrier edges only.
Caution
During this procedure, wear grounding wrist straps to avoid ESD damage to the card.
To reinstall the Ethernet switching module in the chassis, follow these steps:
Step 1
Verify that the captive installation screws are tightened on all modules installed in the switch chassis.
This action ensures that the EMI gaskets on all modules are fully compressed in order to maximize the
opening space for the removed module.
Note
If the captive installation screws are loose, the EMI gaskets on the installed modules will push
the adjacent modules toward the open slot, reducing the opening size and making it difficult to
install the removed module.
Step 2
Fully open both ejector levers on the module being installed. (See
Figure 35
.)